Results
The LCC power LED turns on.
Figure 11 LCC power LED
CL5986
#
#
Power/cooling module replacement
This section describes how to replace a power/cooling module.
Removing a faulted power/cooling module
Before you begin
Identify the faulted power/cooling module by the amber fault LED.
Figure 12 Fault LED on an AC power/cooling module
CL5987
#
#
About this task
NOTICE
Access to the disks in your enclosure will time out and the disks will spin down two
minutes after a power cooling module is removed from the enclosure. While the system can
continue operating on a single power supply, the loss of a module’s two blowers causes the
DAE to power down unless you replace the module within two minutes. When replacing both
cooling modules, ensure the green light on one module has been steadily on for at least 5
seconds before removing power from the second module.
Procedure
1. Attach an ESD wristband to your wrist and the enclosure.
FRU Removal and Replacement
Dell EMC FS25 SSD Shelf Guide Field Replacement Unit Guide
25
Summary of Contents for FS25