INTRODUCTION & MACHINE SPECIFICATIONS
The Avenger 1
0
00-
3
LP and NG fired system can tackle the toughest industrial cleaning tasks. Standard features
include dual belt driven triplex ceramic plunger pumps with low-water shut-off, 4.5 minute system shut down protection plus
many more features, all built into a compact space-saving design. When you need a quick and efficient cleaning system
in your maintenance program, you need the Avenger.
5.0
1500
230-1 Ø
23
30
NG
469,000
140
0
F RISE
5 HP
Triplex Plunger
1/4"
Tubing 7/8 X 12 GA
6 P/C 193 FT
Trigger
50' Wire Braid
L51"xW22 1/2"xH51 3/4"
625 LBS
Flow Rate (GPM)
Pressure (Psi)
Volts
Amps
Min. Circuit Amp
Fuel
BTUH input
Temp.
Motor
Pump
Metering Valve
Heat Exchanger
Coil
Spray Control
Hose
Dimensions (in)
Weight (lbs)
3
.0
1
000
12
0 -1 Ø
18
20
LP
36
7
,000
140
0
F RISE
5 HP
Triplex Plunger
Trigger
50' Wire Braid
L51"xW22 1/2"xH51 3/4"
625 LBS
5.0
1500
230 -1 Ø
23
30
LP
489,000
140
0
F RISE
5 HP
Triplex Plunger
1/4"
Tubing 7/8 X 12 GA
6 P/C 193 FT
Trigger
50' Wire Braid
L51"xW22 1/2"xH51 3/4"
625 LBS
1
000 -
3
LP
091
52
A
1500 - 5 NG
09145A
1
000 -
3
NG
091
51
A
1500 - 5 LP
09146A
3
.0
1
000
12
0 -1 Ø
18
20
NG
2
5
5
,000
140
0
F RISE
2
HP
Triplex Plunger
1/4"
Tubing 7/8 X 12 GA
6 P/C 193 FT
Trigger
50' Wire Braid
L51"xW22 1/2"xH
48
6
00
LBS
Summary of Contents for Avenger 1000-3 LP
Page 19: ...Page 19 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 1 Machine Layout...
Page 20: ...Page 20 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 2...
Page 22: ...Page 22 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 3...
Page 24: ...Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 4...
Page 26: ...DELCO Avenger 1000 3 NG LP Single Phase Pump Drawing...
Page 28: ...DELCO Avengers 1000 3 NG LP Single Phase Electrical Schematic...
Page 30: ...1111 E Lake Francis Dr Siloam Springs AR 72761 1 800 BUY DELCO...