background image

Page 6

 WARNING:

Injury to the operator or bystanders could occur if the machine is operated without all of the guards being in

place on the unit.   When operating the machine, all guards must be in place.

 WARNING:

Operating a pressure washer under high pressure without a securely fastened hose, gun and spray nozzle(s)

could result in bodily injury or property damage.  Make sure the spray nozzle, gun  and  hose are securely

fastened before operating the machine.  Do not remove the nozzle or disconnect the high pressure hose while

the system is pressurized and/or running.

 WARNING:

Machines have moving parts and hot areas that can cause injury.   Keep hands, feet, and loose clothing away

from the pressure washer while it is running.  After use, allow an adequate amount of cool-down time before

attempting to perform any maintenance or service to this unit.

 WARNING:

Failure to wear safety goggles and protective clothing when operating a pressure washer reduces operator

safety.  Always wear safety goggles and protective clothing when the machine  is running  or when operating

machine.

 WARNING:

Operating this pressure washer without the appropriate decals could result in operator injury or damage.  Make

sure all labels and instructional information are fastened to the machine.  Get new labels and decals from your

Delco distributor.

 WARNING:

Any alterations or modifications of this machine could result in damage to the machine or injury to the operator or

other bystanders.  Alterations or modifications not authorized by the manufacturer voids any and all warranties

and liabilities.

 

CAUTION:

Electrical damage can occur if the machine is exposed  to direct and/or over spray.   Always point the wand

toward the object being cleaned.

 CAUTION

:

Using an extension cord with your pressure washer will result in a voltage drop and loss of power. Use of an

extension cord is not recommended.

 CAUTION

:

Use of this machine to move other objects or to climb on could result in injury or damage.

 CAUTION

:

Operating a pressure washer when the pump is low on oil could cause pump damage.  Always check your oil

before using the machine.  Use SAE 30 weight oil.

 CAUTION

:

Operating a pressure washer with insufficient water flow can damage the pump.  Water should be turned on full-

force to avoid insufficient water flow.

 CAUTION

:

Pump damage could occur if the pressure washer is ran for more than five (5) minutes with the trigger released

(closed).

 CAUTION:

Maintenance and repairs performed by unauthorized personnel will void your warranty.   Servicing of this unit

must always be referred to an authorized Delco distributor.

 CAUTION

:

Maintenance and repairs performed by unauthorized personnel could result in damage or injury.

Servicing of this unit must always be referred to an authorized Delco distributor.

 CAUTION:

Your machine warranty will be voided if anything other than genuine Delco parts are used on  your pressure

washer.  Always use Delco parts for replacement.

Summary of Contents for Avenger 1000-3 LP

Page 1: ...Avenger 1000 3 NG LP 2HP Single Phase Operators Manual and Replacement Parts Book Pressure Washers Delco Pressure Washers LIT AVEN 1000 3 DEL...

Page 2: ...as with all mechanical equipment it requires proper installation operation and maintenance as outlined in this manual The Operators Manual has been written for your benefit For your safety and the saf...

Page 3: ...90 days whichever is longer Defective parts replaced under this war ranty are the property of DELCO Cleaning Systems LLC 6 All warranty service will be performed by a trained technician employed by an...

Page 4: ...uctions 6 Operating Instructions 8 Maintenance 9 How to Correct Problems in the Machine 12 Assembly Drawing No 1 15 Assembly Drawing No 2 16 Parts List 17 Assembly Drawing No 3 18 Parts List 19 Assemb...

Page 5: ...explosion Only fill the fuel tank in an open area Do not fill the tank near open flames or while the unit is running Do not smoke while filling the tank Do not over fill the tank Wipe up any spills T...

Page 6: ...this machine could result in damage to the machine or injury to the operator or other bystanders Alterations or modifications not authorized by the manufacturer voids any and all warranties and liabi...

Page 7: ...12 GA 6 P C 193 FT Trigger 50 Wire Braid L51 xW22 1 2 xH51 3 4 625 LBS Flow Rate GPM Pressure Psi Volts Amps Min Circuit Amp Fuel BTUH input Temp Motor Pump Metering Valve Heat Exchanger Coil Spray Co...

Page 8: ...ING Adequate oxygen is needed for proper combustion or dangerous carbon monoxide can result GAS FIRED UNITS Natural gas units operate on 3 1 2 of water column pressure at the solenoid valve and it mus...

Page 9: ...or larger Refer to chart on page 4 Electrical CAUTION This machine must be electrically grounded 1 Connect only to grounded outlets with 30 ampere 230 volt a c alternating current 60 Hz single phase...

Page 10: ...meter B open windows C do not touch electrical switches D extinguish all open flames E immediately call your gas supplier 4 When using L P gas the Control must be equipped with a regulator Make sure t...

Page 11: ...ell gas follow these rules a Get all people out of building b DO NOT light matches DO NOT turn electric lights or switches on or off in area DO NOT use an electric fan to remove gas from area c Shut o...

Page 12: ...rk gap 7 64 NOTE When the trigger is released for more than 4 5 minutes the machine will shut off You must turn the control switch to the OFF position then ON to restart The timer is to protect the pu...

Page 13: ...procedure 1 Locate the oil dipstick in the plug on the top of the pump 2 Turn the oil plug counterclockwise 3 Wipe the dipstick with a clean cloth 4 Screw the dipstick in Pull it back out and check f...

Page 14: ...he coils is caused by mineral deposits from the water and occurs much faster in hard water areas and with heavier machine usage Lime build up can also be caused by inferior cleaning compounds DANGER F...

Page 15: ...enance descaling of pops off at relief valve coils High pressure nozzle Remove nozzle at tip of gun and clean Flush There is has been water in the oil and The oil seal is worn Contact an authorized De...

Page 16: ...ontact an authorized Delco service person V packings Contact an authorized Delco service person The pump is noisy There is air in the suction line Check the water supply Make sure all fittings are tig...

Page 17: ...r plugged pilot orifice Contact an authorized Delco service person Faulty pilot valve Contact an authorized Delco service person Faulty wiring Contact an authorized Delco service person Faulty ignitio...

Page 18: ...______________________________________________________ ________________________________________________________________________________________________________ ________________________________________...

Page 19: ...Page 19 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 1 Machine Layout...

Page 20: ...Page 20 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 2...

Page 21: ...tting 1 2 Female x 1 2 Male x x x x 47 54159A 1 Nipple Pipe 1 2 x 6 x x x x 48 56118A 1 Manifold Unloader 3 4 Brass x x x x 49 59404A 1 Valve Unloader x x 199126 1 Valve Unloader x x 50 170860 8 Washe...

Page 22: ...Page 22 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 3...

Page 23: ...96312 1 8 0 x 25 x x x 24 170014 1 Plug Pipe 1 2 Brass x x x x 25 170265 1 Tee 1 2 x 1 2 x 3 8 Galv x x x x x x x x 4 p m a l C 3 1 2 0 2 2 7 6 2 27 720271 1 Adapter 1 4 h to 1 4 mpt x x x x 28 170034...

Page 24: ...Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 4...

Page 25: ...x 3 4 x x x x 25 29661A 1 Panel Rear Control x x x x 26 171101 4 Nut Whiz Lock 3 8 16 x x x x 27 29667A 1 Bracket Control Panel x x x x 29 198605 1 Transformer 440V 240V 24V x x x x 29a 193775 1 Fuse...

Page 26: ...DELCO Avenger 1000 3 NG LP Single Phase Pump Drawing...

Page 27: ...g n i t c e n n o C 9 2 0 0 5 P I 6 2 27 IP 500 31 Socket Cap Screw M6 x 30 5 Ref Part No Description Qty Ref Part No Description Qty 1 r e v o C r a e R e s a c k n a r C 3 3 0 0 5 P I 8 2 1 e g u a...

Page 28: ...DELCO Avengers 1000 3 NG LP Single Phase Electrical Schematic...

Page 29: ...__________________________________________________ ________________________________________________________________________________________________________ ____________________________________________...

Page 30: ...1111 E Lake Francis Dr Siloam Springs AR 72761 1 800 BUY DELCO...