Page 8
HOW TO PREPARE THE MACHINE FOR OPERATION
NOTE: Following delivery of your Delco pressure washer, inspect the unit for shipping damage.
ASSEMBLY
1. Uncrate machine. Remove cleaner, parts package, gun and hose from shipping carton.
2. Assemble cleaner, gun, and hose. Do not install the pressure nozzle at this time.
3. Install the draft divertor.
4. Refer to the machine drawing in the service section for specific locations of parts you assemble.
INSTALLATION *(Read tags on junction box and gas valve)
1. Do not install the machine in small confined areas, near exhaust fans or in a wash bay where the unit could be
subjected to overspray and cleaning chemicals. Install only in well ventilated areas where adequate flow of air is
available. Adequate oxygen is needed for combustion or dangerous carbon monoxide will result. Stationary units
should be installed in accordance with local plumbing and electrical codes.
2. In all installations, this machine must be vented to the outside with a draft divertor and rain protection.
3. This machine is designed to be installed indoors and must be protected from any direct spray or overspray of
water.
WARNING: Adequate oxygen is needed for proper combustion or dangerous carbon monoxide can result.
GAS FIRED UNITS:
Natural gas units operate on 3-1/2" of water column pressure at the solenoid valve, and it must have 9" water column
or 5 oz.pressure supplied to the unit at the inlet. The water column check points are as follows: Check the 3-1/2"
water column pressure from the plug on the bottom of the solenoid valve with the burner operating. The water column
pressure is checked with a manometer. A gas shut-off valve should be installed on the gas line, with a union between
the shut-off and the unit. Also a sediment trap should be installed after the shut-off valve.
Standard butane or propane gas fired units operate on 11" W.C. Use a gas Manometer when checking gas pressure
or when making adjustments to the regulator. For top efficiency, a 100 lb. or larger gas bottle should be used.
Minimum gas line iron pipe size required for gas supply per length of gas line from the meter (Natural Gas). (Based on
a pressure drop of 0.3" water column pressure and 0.6 specific gravity.)
NOTE: Do not use flexible gas lines. Check total BTU consumption to be assured of proper gas supply to operate
pressure washer.
Pipe
Length
10
20
30
40
50
60
70
80
100
125
150
175
200
Feet
Pipe
Diameter 1
1
1
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
1-1/2
1-1/2 1-1/2
Inches
Summary of Contents for Avenger 1000-3 LP
Page 19: ...Page 19 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 1 Machine Layout...
Page 20: ...Page 20 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 2...
Page 22: ...Page 22 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 3...
Page 24: ...Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 4...
Page 26: ...DELCO Avenger 1000 3 NG LP Single Phase Pump Drawing...
Page 28: ...DELCO Avengers 1000 3 NG LP Single Phase Electrical Schematic...
Page 30: ...1111 E Lake Francis Dr Siloam Springs AR 72761 1 800 BUY DELCO...