MAINTENANCE

1. Use a water softener on your water system if it is known to be high in mineral content.
2. Use only high quality Delco chemicals and follow the manufacturer's mixing instructions.
3. The cleaner should be flushed thoroughly after using the chemical solutions.
4. Follow the fuel specifications as outlined in the machine specifications.
5. Clean the strainer screen in the hose connection at float tank periodically.
6. Pump lubricant:  Periodically check the oil level.  Change the oil after 50 hours of operation, and then after every

500 hours.  Use SAE 30 weight non-detergent oil.

7. Use teflon tape or approved sealer on the plumbing connections when reassembling to prevent leakage.

 CAUTION: If the machine is to be out of service for a long period of time, we recommend that the system be flushed

out with anti-freeze water solution.  Do not run the pump dry for extended periods of time or severe

damage will occur.

8. Deliming coils:  Periodic flushing of the coils is recommended to extend coil life and prevent lime build up.  See

note on page 11.

How To Check The Oil

It is critical that the oil in your pump be checked regularly.  To check the oil follow this procedure:
1. Locate the oil dipstick in the plug on the top of the pump.
2. Turn the oil plug counterclockwise.
3. Wipe the dipstick with a clean cloth.
4. Screw the dipstick in.  Pull it back out and check for the oil level mark.  The oil level should be at the top mark.
5. If the oil is below the notch, add SAE 30 weight, non-detergent oil.
6. Put the dipstick back into the hole.
7. Turn the plug clockwise until it stops.

NOTE: Change the oil after the first 50 hours of use and then after every 500 hours of use.  SAE 30 weight oil must be

used.

Freeze-Up Prevention:

To prevent freeze-up follow these instructions:
1. Drain the float tank.
2. Remove the spray nozzle from the wand.
3. Mix antifreeze concentrate and water in a large container.  Read the recommended mixing instructions given with

the antifreeze.

4. Fill the float tank with the antifreeze mixture.
5. Put the end of the chemical line in the float tank.  Fully open the metering valve.
6. Turn the control switch to position one.
7. Let the pump run until the antifreeze moves through the pump, coils, and pressure hose.

NOTE: The trigger on the gun must be pulled to allow antifreeze to pass through the coils, and then the trigger must be

released to allow the antifreeze to pass through the bypass line.

8. Turn the control switch to the "O" position and close the metering valve.
9. Unplug the cord and put the machine in a dry building.

Summary of Contents for Avenger 1000-3 LP

Page 1: ...Avenger 1000 3 NG LP 2HP Single Phase Operators Manual and Replacement Parts Book Pressure Washers Delco Pressure Washers LIT AVEN 1000 3 DEL...

Page 2: ...as with all mechanical equipment it requires proper installation operation and maintenance as outlined in this manual The Operators Manual has been written for your benefit For your safety and the saf...

Page 3: ...90 days whichever is longer Defective parts replaced under this war ranty are the property of DELCO Cleaning Systems LLC 6 All warranty service will be performed by a trained technician employed by an...

Page 4: ...uctions 6 Operating Instructions 8 Maintenance 9 How to Correct Problems in the Machine 12 Assembly Drawing No 1 15 Assembly Drawing No 2 16 Parts List 17 Assembly Drawing No 3 18 Parts List 19 Assemb...

Page 5: ...explosion Only fill the fuel tank in an open area Do not fill the tank near open flames or while the unit is running Do not smoke while filling the tank Do not over fill the tank Wipe up any spills T...

Page 6: ...this machine could result in damage to the machine or injury to the operator or other bystanders Alterations or modifications not authorized by the manufacturer voids any and all warranties and liabi...

Page 7: ...12 GA 6 P C 193 FT Trigger 50 Wire Braid L51 xW22 1 2 xH51 3 4 625 LBS Flow Rate GPM Pressure Psi Volts Amps Min Circuit Amp Fuel BTUH input Temp Motor Pump Metering Valve Heat Exchanger Coil Spray Co...

Page 8: ...ING Adequate oxygen is needed for proper combustion or dangerous carbon monoxide can result GAS FIRED UNITS Natural gas units operate on 3 1 2 of water column pressure at the solenoid valve and it mus...

Page 9: ...or larger Refer to chart on page 4 Electrical CAUTION This machine must be electrically grounded 1 Connect only to grounded outlets with 30 ampere 230 volt a c alternating current 60 Hz single phase...

Page 10: ...meter B open windows C do not touch electrical switches D extinguish all open flames E immediately call your gas supplier 4 When using L P gas the Control must be equipped with a regulator Make sure t...

Page 11: ...ell gas follow these rules a Get all people out of building b DO NOT light matches DO NOT turn electric lights or switches on or off in area DO NOT use an electric fan to remove gas from area c Shut o...

Page 12: ...rk gap 7 64 NOTE When the trigger is released for more than 4 5 minutes the machine will shut off You must turn the control switch to the OFF position then ON to restart The timer is to protect the pu...

Page 13: ...procedure 1 Locate the oil dipstick in the plug on the top of the pump 2 Turn the oil plug counterclockwise 3 Wipe the dipstick with a clean cloth 4 Screw the dipstick in Pull it back out and check f...

Page 14: ...he coils is caused by mineral deposits from the water and occurs much faster in hard water areas and with heavier machine usage Lime build up can also be caused by inferior cleaning compounds DANGER F...

Page 15: ...enance descaling of pops off at relief valve coils High pressure nozzle Remove nozzle at tip of gun and clean Flush There is has been water in the oil and The oil seal is worn Contact an authorized De...

Page 16: ...ontact an authorized Delco service person V packings Contact an authorized Delco service person The pump is noisy There is air in the suction line Check the water supply Make sure all fittings are tig...

Page 17: ...r plugged pilot orifice Contact an authorized Delco service person Faulty pilot valve Contact an authorized Delco service person Faulty wiring Contact an authorized Delco service person Faulty ignitio...

Page 18: ...______________________________________________________ ________________________________________________________________________________________________________ ________________________________________...

Page 19: ...Page 19 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 1 Machine Layout...

Page 20: ...Page 20 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 2...

Page 21: ...tting 1 2 Female x 1 2 Male x x x x 47 54159A 1 Nipple Pipe 1 2 x 6 x x x x 48 56118A 1 Manifold Unloader 3 4 Brass x x x x 49 59404A 1 Valve Unloader x x 199126 1 Valve Unloader x x 50 170860 8 Washe...

Page 22: ...Page 22 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 3...

Page 23: ...96312 1 8 0 x 25 x x x 24 170014 1 Plug Pipe 1 2 Brass x x x x 25 170265 1 Tee 1 2 x 1 2 x 3 8 Galv x x x x x x x x 4 p m a l C 3 1 2 0 2 2 7 6 2 27 720271 1 Adapter 1 4 h to 1 4 mpt x x x x 28 170034...

Page 24: ...Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 4...

Page 25: ...x 3 4 x x x x 25 29661A 1 Panel Rear Control x x x x 26 171101 4 Nut Whiz Lock 3 8 16 x x x x 27 29667A 1 Bracket Control Panel x x x x 29 198605 1 Transformer 440V 240V 24V x x x x 29a 193775 1 Fuse...

Page 26: ...DELCO Avenger 1000 3 NG LP Single Phase Pump Drawing...

Page 27: ...g n i t c e n n o C 9 2 0 0 5 P I 6 2 27 IP 500 31 Socket Cap Screw M6 x 30 5 Ref Part No Description Qty Ref Part No Description Qty 1 r e v o C r a e R e s a c k n a r C 3 3 0 0 5 P I 8 2 1 e g u a...

Page 28: ...DELCO Avengers 1000 3 NG LP Single Phase Electrical Schematic...

Page 29: ...__________________________________________________ ________________________________________________________________________________________________________ ____________________________________________...

Page 30: ...1111 E Lake Francis Dr Siloam Springs AR 72761 1 800 BUY DELCO...

Reviews: