Page 11
Figure # 1
13. If control has been exposed to water in any way, it must be replaced.
14. Keep combustible material away from gas machine. Keep burner area clean and free of dust and lint.
15. If gas valve fails to shut off, do not turn off electrical power. Turn off gas supply allowing water pump to continue
running until system has cooled. Replace control.
16. The manual valve should not be used to adjust gas flow.
17. All components must be securely mounted with screws, bolts, etc., within the machine.
3 in. 176.2 mm
MINIMUM
3 in. 176.2 mm
MINIMUM
3 in. 176.2 mm
MINIMUM
GAS
VALVE
GAS
VALVE
GAS
VALVE
TUBING
GAS
SUPPLY
DROP
HORIZONTAL
PIPED
GAS
SUPPLY
PIPED
GAS
SUPPLY
DROP
HORIZONTAL
RISER
RISER
ALL BENDS IN METALLIC TUBING SHOULD BE SMOOTH
The following warning applies to installations using L.P., Propane Gas:
WARNING: To avoid possible injury, fire and explosion, please read and follow these precautions and all instruc-
tions on this machine before lighting the pilot. This machine uses L.P. (Propane) gas which is heavier
than air and will remain at floor level if there is a leak. Before lighting, sniff at
floor level. If you smell
gas, follow these rules:
a) Get all people out of building.
b)
DO NOT
light matches.
DO NOT
turn electric lights or switches on or off in area.
DO NOT
use an electric fan to
remove gas from area.
c) Shut off gas at L.P. tank outside of building.
d) Phone the gas company and fire department. Ask for instructions.
Before hanging up, give your name, address, and phone number.
DO NOT
go back into the building. If help is
coming wait for them to arrive.
If your L.P. tank runs out of fuel, turn off gas at the machine. After L.P. tank is refilled, machine must be re-lit accord-
ing to manufacturer's instructions. If the gas control has been exposed to
WATER
in any way,
DO NOT
try to use it. It
must be replaced.
DO
NOT
attempt repair on gas valve . It must be replaced.
DO NOT
attempt repair on gas
control or machine. Call an authorized Delco distributor for repairs.
Tampering is DANGEROUS and voids all warranties.
18. Do not short gas valve terminals. This may burn out the controls.
19. Make certain all wiring connections are tight. The spark ignitor and electrode connection to the ignition control
must be tight, or damage to the unit may result.
20. The ignition control and pilot burner must both be chassis grounded.
21. Handle the pilot-electrode assembly carefully. If damaged, replace entire assembly. The correct spark gap
should be 7/64" to 1/8".
Summary of Contents for Avenger 1000-3 LP
Page 19: ...Page 19 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 1 Machine Layout...
Page 20: ...Page 20 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 2...
Page 22: ...Page 22 Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 3...
Page 24: ...Delco Avengers 1000 3 NG LP Single Phase Assembly Drawing No 4...
Page 26: ...DELCO Avenger 1000 3 NG LP Single Phase Pump Drawing...
Page 28: ...DELCO Avengers 1000 3 NG LP Single Phase Electrical Schematic...
Page 30: ...1111 E Lake Francis Dr Siloam Springs AR 72761 1 800 BUY DELCO...