SECTION 2
Installation (Continued)
2D Mounting the TrioPure
TM
IMPORTANT:
A qualified swimming pool professional and
certified electrician must install the TrioPure
TM
Sanitation
System or the warranty is void
. Refer to local building codes
for any additional requirements. If you need assistance in
finding a qualified installer please contact our customer ser-
vice department at 1-800-676-1335, ext. 249, or visit www.
delozone.com.
Step 1 - Pick a Mounting Location that Meets the Following
Criteria:
•
Is ten ft. (10’) minimum from the edge of pool.
•
Is no more than 8’ above or 3’ below water level.
•
Allows clearance on all sides for ventilation, installation
and maintenance (review Sections 2E Plumbing and 2F
Electrical). A clearance of 2’ minimum is required at the
bottom of the unit for access to the chlorinator cell.
•
Is not above any heat source such as a heater or pump,
and is not in a box.
•
Is less than 8’ from the bypass manifold.
•
••
If mounting on a post, must be centered on a flat panel
of waterproof material at least 18” by 24”.
•
Out of direct sunlight as much as possible.
Step 2 - Prep the Mounting Location
•
Mark the bolt pattern on the mounting surface: 10” wide
by 14.75” high.
•
Drive the bottom two bolts (1/4 - 20 galvanized hex bolts
recommended) so that the heads are sticking out about
1/4” from the mounting surface.
Step 3 - Secure the TrioPure
™
to the Mounting Surface
•
Place the unit on the bottom bolts so that they fit in the
slots on the bottom of the white enclosure.
•
Holding the unit in place, drive the remaining two bolts
in the mounting holes at the top of the enclosure.
3
TrioPure
TM
Sanitation System
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
2E Plumbing
2e-1 Installing the TrioPure
TM
Bypass Manifold
•
Do not install the Bypass Manifold with the 2” section in
a vertical position. The 3/4” line orientation is optional,
but the 2” plumbing must be horizontal.
•
The arrow on the Bypass Manifold DEL check valve must
go in the direction of water flow.
•
••
Always plumb the Bypass Manifold after the pool filter.
•
For pool/spa combinations: plumb the Bypass Manifold
in the pool leg after the 3-way valve whenever possible.
See Section 2E-2, Figure 2.
•
For pool only: plumb the Bypass Manifold between the
filter and heater. See Section 2E-2, Figure 1.
•
Plumb the Bypass Manifold to the TrioPure
™
Water In
union using spa-flex tubing or rigid PVC.
○ Length should not exceed 8’
○ Installation of an isolation ball valve in the line is
required
•
••
Plumb the TrioPure
™
Water Out union to the pool return
using spa-flex tubing or rigid PVC.
○ Installation of an isolation ball valve in the 3/4” line
is required
○ A light-duty check valve must be installed in the return
line if the TrioPure
™
is installed below the water line
•
Dedicated Return (preferred):
○ Length of 3/4” diameter line should not exceed 8’; use
1-1/2” diameter plumbing from the equipment pad
to the pool, do not exceed 75’ in total length
•
Return to Pool System Plumbing (retrofit):
○ Length of 3/4” diameter line should not exceed 8’
○ Keep the number of 90s in the line to a minimum
○ Do not plumb the return T-fitting in the same leg as an
in-floor cleaning system (Paramount, Caretaker, etc.)
•
At the return line’s termination point in the pool, use the
least restrictive fitting possible to minimize backpressure
(an anti-vortex drain cover is recommended).
Ozone is drawn into
water stream
Look for bubbles here to
verify ozone sanitation