Problem
Cause
Solution(s)
A) Water flow to the
TrioPure
TM
was restricted
due to an obstruction or
a suction side air leak.
A) Turn off the TrioPure
TM
and main pool circuit breaker.
Check pool equipment for obstructions and/or air
leaks and remove as necessary. Check filter, clean or
pump to waste as required. Turn the pool pump on and
then the TrioPure
TM
on – both
Water Flow
and
Ozone
Production
cell indicators should return to green.
Problem
Cause
Solution(s)
A) Water is too hot.
A) Lower the pool’s water temperature to less than
104°F. The
Water Temp
indicator should return to
green when the pool temperature is back within the
TrioPure
™
’s specified limits.
B) Water is too cold.
B) Raise the pool’s water temperature to more than
59°F. The
Water Temp
indicator should return to
green when the pool temperature is back within the
TrioPure
™
’s specified limits.
Note: If you intend to operate the TrioPure™ all winter
without heating the water, turn the
Chlorine Control
knob fully counter-clockwise to the OFF position and
use only the ozone for sanitizing. The
Water Temp
light will remain red until the water temperature is
above 59°F.
C) Temperature sensor
has become
disconnected.
C) Verify connections are correct and secure.
Problem
Cause
Solution(s)
A) The salt chlorinator is
in Cleaning mode.
A) The TrioPure
TM
will shut off power to the salt chlorina-
tor when in Cleaning mode. If the
Chlorine Control
display shows
CL
longer than 24 hours, contact our
telephone support number, 800.676.1335 ext. 293,
for service.
TrioPure
TM
Sanitation System
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
18
Figure 24
Figure 25
Figure 26
B) Turn off the TrioPure
TM
and main pool circuit breaker.
Check the wiring from the flow switch to the main har-
ness on the right side of the enclosure and reconnect
if necessary. Turn the power on to the TrioPure
™
and
main pool circuit breaker and check that both
Water
Flow
and
Ozone Production
cell indicators are green.
C) Call for service.
B) Flow switch has
become disconnected
from the TrioPure
™
enclosure.
C) Internal pump is
inoperable or impellor
is clogged.
Chlorine Production display reads CL
Y
Y
Y
Pb
Pb
CL
Water Flow Indicator turns red and
Chlorine Production flashes Pb and all
03 indicator LEDs turn red.
Water Temperature Indicator turns red
and Chlorine Production displays Pb
and all 03 indicator LED’s stay green.