2F Electrical
IMPORTANT:
Electrical connections must be made by a
certified electrician or certified pool contractor. Use copper
conductors only. Follow all applicable electrical codes.
Connect only to a circuit protected by a Class A GFCI.
Note:
The TrioPure
TM
must be hard-wired to the AC line side
for 24 hour operation
to 120V/60Hz or 240V/60Hz ONLY
using liquid tight fittings/conduit and wire gauges meet
-
ing all applicable electrical codes for the voltage required.
Use a permanent marker to indicate either 120V or 240V
configuration on the side label found on the left side of the
TrioPure
TM
.
Step 1 -
Determine the voltage required for your installation.
Your
TrioPure
TM
is configurable for either 120V or 240V AC.
Step 2
-
For 120V installations, install the 3.0A fuse (3AG
type) into the fuse holder on the right side of the enclosure.
For 240V installations, install the 1.5A fuse (3AG type) into
the fuse holder. The fuses are in the parts bag.
Warning:
Failure to install the correct fuse voids the warranty
and can present a potential fire and/or electrical hazard.
Step 3 -
Open the front clear cover by removing the screw and
opening the latch on the right side of the enclosure.
Step 4 -
Remove the front display plate by pulling off the
Chlorine Control Knob
and unscrewing four (4) Phillips head
6-32 screws. Locate the terminal block (TB-1).
Step 5
- The main power wiring should be routed through the
½” hole on the left side of the enclosure using appropriate
liquid tight strain relief or conduit (not supplied).
Step 6 -
Connect the main wires to TB-1 as shown in
Figure 3
for 120V installations or
Figure 4
for 240V installations.
Step 7 -
Connect the local common bonding grid in the area
of the swimming pool, spa or hot tub to the bonding lug (on
the left exterior of the unit) with an insulated or bare solid
copper conductor not smaller than 8 AWG (US) or 6 AWG
(Canada). For other countries, refer to applicable electrical
codes.
Step 8 -
Attach the front display plate with the four (4) Phil-
lips head 6-32 screws. Replace the Chlorine Control Knob
onto the extended “D” control shaft. Ensure that the ON/
OFF switch is in the “OFF” position. Close and latch the
clear cover.
6
TrioPure
TM
Sanitation System
Figure 3 Terminal Block 120V Configurations
Figure 4 Terminal Block 240V Configurations
120V Line
Voltage Wiring
240V Line
Voltage Wiring