SECTION 4
Operation
4A Initial Start-Up Procedure
Step 1
-
Before starting the TrioPure
™
, manually add
chlorine to the water for the first week to a minimum level
of 1 ppm and ensure that the water chemistry, water
temperature and salt level (salinity) and adjust as needed
– all must be within the limits specified in Section 5B,
Monitoring & Maintenance before starting the TrioPure
™
.
Step 2
- Turn on main pool pump before starting the
TrioPure
™
Step 3
-
Become familiar with the controls, indicators, and
features of the TrioPure™. See Figure 8 below (TrioPure™-50
shown).
1) Chlorine Production
- Normal Indicator Messages: OF =
Chlorine Control turned off; 1-10 = Level of chlorine produc-
tion; CL = Chlorinator plates are in “clean mode” (down time
between polarity changes)
Error Indicator Messages (refer to Section 6A, Troubleshoot-
ing, Page 17): Pb = Chlorinator shut off due to problem; OL
= Current over limit
2)
Chlorine Control
- The Chlorine Control Knob controls
the level of chlorine production. Turn the knob clockwise to
increase the amount of chlorine generated and counterclock-
wise to decrease the amount of chlorine generated.
3)
Low Salt Indicator
- The Low Salt indicator is normally
off and not lit. The Low Salt indicator blinks red when the
pool should be checked for low salinity (Warning-always check
salinity level with a test strip or digital meter before adding
salt).
4)
High Salt Indicator
- The High Salt indicator is normally
off and not lit. The High Salt indicator blinks red when the pool
should be checked for high salinity. (Warning-always check salin-
ity level with a test strip or digital meter before diluting water).
5)
Ozone Production Indicators
- The normal operating
color of the TrioPure’s
™
Oз LED indicators is green. A red LED
indicates that the Ozone Cell is not operating (refer to Section
6A, Troubleshooting).
The TrioPure
™
-25 has two Oз cell LEDs while theTrioPure
™
-50
has four Oз cell LEDs. Note: If the Water Flow indicator is RED,
all Oз cell LEDs will turn red as well.
6)
Water Flow Indicator
- The Water Flow LED indicator is
normally green. A red Water Flow LED indicates insufficient
water flow. Note: When water flow is interrupted, both chlorine
and ozone production is halted. A Pb error is displayed. Oз LED
indicators turn red, and the pump is shut off.
7)
Water Temperature Indicator
- The Water Temperature
LED indicator is normally green (water between 50-108˚ F).
A red Water Temperature LED indicates water temperature
is either too low or high. When water temperature is outside
specified range, a Pb error is displayed. The TrioPure
™
ozone
cells and pump continue to run.
8) On/Off switch
9) Main fuse
10) Serial Number
1
2
5
10
9
8
3
4
7
6
Figure 8