SES Installation & Operations Manual
1
INSTALLATION INSTRUCTIONS
1. Overview
The Spa Solar Eclipse is a UV/Ozone sanitation unit designed for use
in portable spas and to be controlled by the spa’s equipment pack.
Please contact DEL Customer Support if the Spa Solar Eclipse is
used in an application other than a portable spa.
2. Mounting
a. Use the two mounting holes located internally on the back panel of
the Spa Solar Eclipse (Figure 1).
b. Mount the Spa Solar Eclipse to the spa frame with #8 hardware.
The preferred mounting orientation is shown in Figure 2. Connect
water inlet at the bottom. Contact DEL Ozone for other installation
options.
3. Plumbing
DEL Ozone recommends that the Ozone Injector be installed
upstream of the Spa Solar Eclipse so the ozone can interact with the
UV light. This interaction leads to Advanced Oxidation Process which
will improve sanitation. However, the Spa Solar Eclipse will function
properly if the Ozone Injector is installed downstream.
a. Connect ozone compatible tubing (1/4” internal diameter) to the
open hose barb on the Spa Solar Eclipse
b. Run tubing to the Ozone Injector or appropriate vacuum source.
i. If the Spa Solar Eclipse is mounted above the water line,
tubing may be run directly to the vacuum source.
Figure 1: System Overview
Allow vertical clearance
for lamp removal
(approximately 12”)
Mounting Hole
Power LED
UV LED
Ozone Indicators
(2x)
Air Intake Filter
Ozone Out
Bonding Lugs
Inlet
Mounting Hole
Outlet