background image

SES  Installation & Operations Manual

3

verify that small bubbles can be seen in the return flow. Finally, turn 
the Spa off and make sure that the POWER and UV indicator lights 
are not illuminated.

6. Maintenance

WARNING:

 Before performing any maintenance on the Spa Solar 

Eclipse, make sure the spa is shut down.

6A.  UV Lamp Removal (see Figure 3)

 

If the Green Power Indicator is on, but the Blue UV Lamp Indicator is 
off, the UV lamp needs to be replaced. For maximum UV sanitation 
effect, replace the UV Lamp every 18 months.

i.  Make sure the unit is disconnected from power and the lamp 

has cooled before starting maintenance.

ii.  Open the Spa Solar Eclipse by removing the two front screws 

and loosening the two Enclosure Screws on the Upper 
Enclosure Assembly. Pull the Cover from the Enclosure Base.

iii.  Disconnect the Lamp Connector attached to the lamp wires.
iv.  Gently pull on the Lamp Wires until the top of the UV Lamp is 

out of the Lamp Retainer. Grasp the white ceramic end of the 
UV Lamp and pull until it is fully removed. If the UV Lamp will 
be reused, AVOID TOUCHING THE UV LAMP GLASS WITH 
YOUR BARE HANDS. Handle the lamp carefully and set aside. 
If discarding, dispose of properly (see the following note). 

Figure 3: Spa Solar Eclipse Exploded View

UV Lamp

Sealing Ring

Quartz Tube

Lamp Retainer

Retainer Screw

Summary of Contents for spa solar eclipse

Page 1: ...Installation Manual 4 2298 01 Rev B Ozone UV Sanitation 800 676 1335 o3info delozone com www delozone com EPA Estab No 071472 CA 001 ...

Page 2: ...then a G F C I must be installed between the Spa Solar Eclipse and the electrical supply WARNING To reduce the risk of electrical shock if the power cord is damaged replace the entire unit immediately The Spa Solar Eclipse must be mounted under the spa skirt sheltered from enviornmental elements rain sun sprinklers Plastic ozone supply tubing is available with the Spa Solar Eclipse Never replace t...

Page 3: ...TABLE OF CONTENTS Installation Instructions 1 Overview 1 2 Mounting 1 3 Plumbing 1 4 Electrical 2 5 Operation 2 6 Maintenance 3 Warranty 7 ...

Page 4: ...llation options 3 Plumbing DEL Ozone recommends that the Ozone Injector be installed upstream of the Spa Solar Eclipse so the ozone can interact with the UV light This interaction leads to Advanced Oxidation Process which will improve sanitation However the Spa Solar Eclipse will function properly if the Ozone Injector is installed downstream a Connect ozone compatible tubing 1 4 internal diameter...

Page 5: ...r b Where possible route the Spa Solar Eclipse power cord away from other electrical lines Avoid routing the power cord parallel to any low voltage signal wires c Use a minimum 8 AWG solid copper conductor to connect the bonding lug provided on the Enclosure Base to the spa equipment ground 5 Operation If installed correctly the Spa Solar Eclipse will turn on and off as required by the Spa Control...

Page 6: ... from power and the lamp has cooled before starting maintenance ii Open the Spa Solar Eclipse by removing the two front screws and loosening the two Enclosure Screws on the Upper Enclosure Assembly Pull the Cover from the Enclosure Base iii Disconnect the Lamp Connector attached to the lamp wires iv Gently pull on the Lamp Wires until the top of the UV Lamp is out of the Lamp Retainer Grasp the wh...

Page 7: ...ormance The Quartz Tube should be removed from the UV Reactor at least once a year or during a routine spa water change for inspection and cleaning if necessary 6D Quartz Tube Removal and Cleaning CAUTION Wear proper eye and skin protection for servicing glass components NOTE Damage caused by broken quartz tubes is not covered under the Spa Solar Eclipse Limited Warranty CAUTION If broken glass is...

Page 8: ...Follow the directions for safe use and handling of muriatic acid on the acid bottle label Never add water to acid Always add acid to water vii After cleaning the Quartz Tube wash it off with water and wipe dry with a soft towel viii Make sure the inside of the Quartz Tube is dry before installing the UV Lamp Make sure the inside of the Quartz Tube is dry before replacing the UV Lamp s 6E Quartz Tu...

Page 9: ...here are no leaks vii Install the UV Lamp as described in Section 4 viii Reinstall the Upper Enclosure Assembly to the Enclosure Base ix The unit is now ready for normal operation 6F Standard Replacement Parts List i Replacement UV Lamp Assembly 9 1100 01 ii Quartz Tube Replacement Kit 9 1204 01 iii Sealing Ring 7 1871 01 ...

Page 10: ... or implied warranty of fitness for particular purpose and such warranties are hereby disclaimed f DEL Ozone shall not be liable under any circumstances for loss of use of such product loss of profits direct damages indirect damages consequential damages and or incidental damages This warranty gives you specific legal rights You may have other rights which vary from state to state TO OBTAIN WARRAN...

Page 11: ......

Page 12: ... 800 676 1335 o3info delozone com www delozone com EPA Estab No 071472 CA 001 ...

Reviews: