SES Installation & Operations Manual
5
iii. Remove the two Retainer Screws and Retainer Washer from the
top of the Lamp Retainer and pull the Lamp Retainer out of the
UV Chamber Cap.
NOTE:
Any water remaining in the system above the level of the
Spa Solar Eclipse will flow out of the UV Housing once the Lamp
Retainer is removed.
iv. Grasp the inside of the Quartz Tube and pull it out of the
housing. Make sure the Sealing Ring does not get lost during
Quartz Tube removal.
v. Inspect the Quartz Tube for cracks and replace if cracks are
found. Inspect the Sealing Ring for nicks or hardness and
replace if necessary.
vi. Clean the Quartz Tube exterior with a mild solution of muriatic
acid and water in a ratio of four parts water to one part acid
(4:1). DO NOT USE ABRASIVE CLEANERS.
CAUTION: Follow the directions for safe use and handling of
muriatic acid on the acid bottle label. Never add water to acid.
Always add acid to water.
vii. After cleaning the Quartz Tube, wash it off with water and wipe
dry with a soft towel.
viii. Make sure the inside of the Quartz Tube is dry before installing
the UV Lamp.Make sure the inside of the Quartz Tube is dry
before replacing the UV Lamp(s).
6E. Quartz Tube Installation
i. Place the Sealing Ring on the Quartz Tube 3/4 inch from the
open end.
ii. Insert the Quartz Tube partially into the UV Chamber. Place the
Lamp Retainer over the open end of the Quartz Tube and slowly
push in until it is touching the UV Chamber Cap.
iii. Place the Retainer Washers onto the Retainer Screws and
screw the Lamp Retainer Screws until the Lamp Retainer is
completely seated against the UV Chamber Cap.
iv. After pool is refilled, turn the pool ON and check the seal around
the Lamp Retainer for leaks.
v. If the unit leaks, please contact DEL Customer Support at