32
Installation guide
DEiMiC ONE MASTER v1.8
5.3. CENTRAL HEATING (continued)
4. If DHW circulation pump should be controlled by
DEiMiC system, the
pump must have auto start function (after power on pump should start
working). An electrician should be informed about a need to route 3x1,5mm
2
wire to a DHW circulation pump (hot, neutral and ground wire). If the
pump needs another connection, the installer should be informed immediately.
5. The installer of central heating is obligated to deliver a documentation,
which readably describes actuators and assigns heating zones (rooms) to them.
Every single valve must have individual, permanent number.
6. Temperature of the central heating heat supply should be the same for all
floor facings. If heat supply will be mixed (underfloor heating, radiators), a
mixer in the front of the distributors is needed. The mixer must set
maximum safe floor temperature.
7. If there are important reasons, which prevents the activation of the heating
system in way described above, the installer and the investor should be
informed immediately.
We will be grateful for every information, which may affect the proper
operation of the system.
We will be glad to help,
DEiMiC team