9
Installation guide
DEiMiC ONE MASTER v1.8
6. A 1 mm
2
multi-conductor cable should be lead to heating distributors
(number of the cable conductors
= quantity of 2).
7. A UTP cat. 5 cable should be placed in the all switch boxes directly from
an electrical switchgear (if any localization have more than 6 buttons, it
necessary to add one more UTP cat. 5).
8. A UTP cat. 5 cable should be lead to the temperature sensors directly from
an electrical switchgear.
9. Chosen switchable electric socket should be connected directly do an
electrical switchgear.
10. LED and RGB lighting circuits – Power suppliers should placed in an
electrical switchgear; connection: 2 or 4 multi-conductor cable with cable
cross-section adjusted to cables length and lighting power.
11.
Gelled wires only should be placed inside ground and outside the object.
12.
A 2x1 mm
2
wire form an electrical switchgear should be lead to a
gate
electro connector.
Do not use shielded cables to the switches, especially high-class cables.
You should use good quality cables only. Choose UTP cat. 5 cables which
are made from copper.