background image

18 

Installation guide 

DEiMiC ONE MASTER v1.8 

3.4. OUTPUTS CONNECTION – SHUTTERS 

Figure 7. Shutters connection diagram 

Summary of Contents for One Master

Page 1: ...ONE Master Installation guide smart home for everyone ...

Page 2: ...LY CONNECTION 15 3 2 NETWORK CONNECTION 16 3 3 OUTPUTS CONNECTION LIGHTS 17 3 4 OUTPUTS CONNECTION SHUTTERS 18 3 5 OUTPUTS CONNECTIONS GATES GATEWAYS 19 3 6 OUTPUS CONNECTIONS LED LIGHTS 20 3 7 OUTPUTS CONNECTION CONTACTORS 22 3 8 INPUTS CONNETION SWITCHES AND BUTTONS 23 3 9 MOTION SENSORS CONNECTION 24 3 10 EXTENSIONS MODULES CONNECTION 25 4 FIRST START 26 4 1 TEST BUTTON 26 4 2 DEiMiC ONE MOBILE...

Page 3: ...tallation work should be done with power off Every repairs must be performed be authorized service only Device modifications or repairs done by anyone who is not authorized by the producer are forbidden and means lose of the warranty To avoid risk of electrical shock never open the device and do not touch any inside components of the device with your hands For safety reasons it s necessary to obey...

Page 4: ...ve 2002 96 EC The Directive prohibits disposal of waste electrical and electronic equipment with other garbage under penalty of a fine According to the law worn out devices must be separately collected and sorted Customers should contact their local authorities or the seller to get information about disposal of a waste electrical and electronic equipment ...

Page 5: ... extends the system capabilities by adding temperature control functionality and increasing number of the system inputs and outputs The module includes 22 relay outputs 8 dimmable LED outputs 2 relays dedicated to LEDs power suppliers switching 32 discrete inputs and 10 channel temperature controller which contains a output for a recuperator control and a relay for central heating furnace switchin...

Page 6: ...24 V 4 Number of all discrete inputs 55 Number of discrete inputs for motion sensors connection 6 Number of Ethernet ports 1 Number of USB ports 2 Number of extensions headers 1 Power supply 12 V DC min 20 W Dimensions length width height 321x109x54 mm Used space in electric switchgear 18 modules Installation place Electrical switchgear Tab 2 High current relays maximum load Load type Max power Re...

Page 7: ...iC ONE MASTER v1 8 1 3 THE DEVICE PINOUT DESCRIPTION Figure 2 DEiMiC ONE MASTER pinout description POWER SUPPLY LEDS LOW CURRENT OUTPUTS HIGH CURRENT OUTPUTS HIGH CURRENT OUTPUTS INPUTS FOR MOTION SENSORS INPUTS DISCRETE INPUTS ...

Page 8: ...ates heating devices alarms irrigation devices ventilation and sound systems The device is cooperating with motion sensors temperature sensors and switches Thanks to LAN network connection the DEiMiC system can be controlled via tablet or smartphone providing the user all information about the system state from almost every place in the world Figure 3 Smart home system with DEiMiC ONE MASTER ...

Page 9: ...iver nippers for cable cutting digital multimeter connectors crimper cable stripper soldering tool EVERY INSTALLATION WORK SHOLUD BE DONE WITH POWER OFF BEFORE ASSEMBLY IT IS NECESSARY TO READ THE INSTRUCTION ESPECIALLY THE WARNINGS ON PAGE 1 Before assembly it is recommended to prepare a object plane Preparation of the object plane and putting there all system devices switches and sensors will ma...

Page 10: ...commendations 3 Gate driver should be routed from an electrical switchgear according to producer specification UTP cat 5 cable to the controller 4 Every motion sensor should be connected with another UTP cat 5 cable directly from an electrical switchgear 5 One UTP cat 5 cable should be placed between Ethernet router and an electrical switchgear During wires installation it is recommended to ensure...

Page 11: ...ical switchgear 9 Chosen switchable electric socket should be connected directly do an electrical switchgear 10 LED and RGB lighting circuits Power suppliers should placed in an electrical switchgear connection 2 or 4 multi conductor cable with cable cross section adjusted to cables length and lighting power 11 Gelled wires only should be placed inside ground and outside the object 12 A 2x1 mm2 wi...

Page 12: ... current devices should be chosen and installed by a electrician only 3 One protection should be done for every 6 lighting circuits 4 One protection should be done for every 6 shutters 5 DEiMiC system needs one B6 circuit breaker 6 Whole electrical switchgear must be described in details and sent to a investor Every wire connection which differs from above rules must be consulted with the system i...

Page 13: ...ngle terminal d Shutters hot wires led out at two single terminal where first one sets the direction up apply the same rule for roof windows and other mechanisms where direction is controlled by wire connection sequence second one the direction down e Switchable electric sockets hot wires led out at single terminal f Switches UTP cables led to an electrical switchgear with description andenough fr...

Page 14: ...j All terminals leading out to devices which are power supplied by voltage lower than 230 V should be marked and different terminal colors should be used 2 2 4 MARKING 1 All wires should be permanently marked at both sides with a proper distance which ensure description visibility after removing wire isolation 2 Terminals and fuses should be numerated marked 3 Marks must not be duplicated 4 Descri...

Page 15: ...rm installation in accordance with following rules 1 After finishing wiring please check quantity of circuits in terms of included figures 2 A readable description should be prepared in electronic version 3 All doubtful situations should be consulted with the installer 4 All changes introduced by a investor should be immediately reported 5 During start up all lighting circuits should be ended by a...

Page 16: ... 8 2 2 5 GOOD ADVICES continued 7 Check shutters and other drives connections in terms of properly work and terminals direction sequence 8 Temporary installation used by workers should be connected to the switchgear after finishing a connection ...

Page 17: ...15 Installation guide DEiMiC ONE MASTER v1 8 3 EXAMPLES OF WIRING DIAGRAMS 3 1 POWER SUPPLY CONNECTION Figure 4 Power supply connection diagram ...

Page 18: ...16 Installation guide DEiMiC ONE MASTER v1 8 3 2 NETWORK CONNECTION Default IP 192 168 1 99 Figure 5 Network connection diagram ...

Page 19: ...17 Installation guide DEiMiC ONE MASTER v1 8 3 3 OUTPUTS CONNECTION LIGHTS Figure 6 Lights connection diagram ...

Page 20: ...18 Installation guide DEiMiC ONE MASTER v1 8 3 4 OUTPUTS CONNECTION SHUTTERS Figure 7 Shutters connection diagram ...

Page 21: ...19 Installation guide DEiMiC ONE MASTER v1 8 3 5 OUTPUTS CONNECTIONS GATES GATEWAYS Figure 8 Gates and gateways connection diagram ...

Page 22: ...20 Installation guide DEiMiC ONE MASTER v1 8 3 6 OUTPUS CONNECTIONS LED LIGHTS OPTION 1 THE DEVICE SWITCHES LEDS POWER SUPPLIER Figure 9 LEDs connection diagram option 1 ...

Page 23: ...21 Installation guide DEiMiC ONE MASTER v1 8 OPTION 2 LEDS POWER SUPPLIERS EXTERNALLY CONECTED TO MAINS ELECTRICITY Figure 10 LEDs connection diagram option 2 ...

Page 24: ...22 Installation guide DEiMiC ONE MASTER v1 8 3 7 OUTPUTS CONNECTION CONTACTORS Figure 11 Contactors connection diagram ...

Page 25: ...23 Installation guide DEiMiC ONE MASTER v1 8 3 8 INPUTS CONNETION SWITCHES AND BUTTONS Figure 12 Inputs connection diagram ...

Page 26: ...24 Installation guide DEiMiC ONE MASTER v1 8 3 9 MOTION SENSORS CONNECTION Figure 13 Motion sensors connection diagram ...

Page 27: ...n guide DEiMiC ONE MASTER v1 8 3 10 EXTENSIONS MODULES CONNECTION Incorrect connection it may damage the devices Straight Cable must be used rather than Crossover Cable Figure 14 Extension modules connection diagram ...

Page 28: ...OBILE APPLICATION DEiMiC smart home control panel is easy to operate clean look and multitask The DEiMiC system can be controlled via tablet or smartphone providing the user all information about the system state from almost every place in the world DEiMiC company introduced possibility of control of all installations and every single part of the system using easy operated control panel switches p...

Page 29: ... START OF DEiMiC ONE APPLICATION During first application start enter the server address and the code placed on the DEiMiC ONE device For further information and detailed DEiMiC system configuration tutorial please visit our channel https vimeo com deimic ...

Page 30: ... good quality products which limit switches are working properly To ensure proper assembly process please follow the rules below 1 If a drive is not phase controlled contact the technical support before product ordering and assembly to get information about compatibility of the given drive with the DEiMiC system 2 If bridging a roller blind is necessary make sure that it is allowed by the drive te...

Page 31: ...uise in case of a strong wind which may damage it 5 After mounting drives they must operate in full open close range limit switches should be regulated During building commissioning the system installer will connect all roller blinds in purpose of ensure roller blinds control capability and security the construction site The drive producer take responsibility for possible damages caused by missing...

Page 32: ...ol capability of car gates Drives are controlled by the DEiMiC system via relay system which can be open closed or impulse controlled depending on a needs and specification of the given drive Maximum contact load up to 5 A 230 V AC We recommend to use drives with separate contacts which short circuits will make the contacts open stopped and a gate closed stopped ...

Page 33: ...nace automation system which only task is to maintain the given temperature setpoint In rooms with regulated temperature heat supply should be limited with NO 230 V actuator normally open To ensure proper assembly process please follow the rules below 1 Heat distributors location should be shown to an electrician which should be informed about number of heating zones per single distributor so he w...

Page 34: ...umentation which readably describes actuators and assigns heating zones rooms to them Every single valve must have individual permanent number 6 Temperature of the central heating heat supply should be the same for all floor facings If heat supply will be mixed underfloor heating radiators a mixer in the front of the distributors is needed The mixer must set maximum safe floor temperature 7 If the...

Page 35: ...014 1 0 initial release 1 1 added wiring diagrams 05 06 2014 1 4 changed the device more number inputs outputs added functional capabilities 1 5 added new wiring diagrams and information about DEiMiC ONE COMFORT 1 6 changed information about extension modules 1 7 added industry guidelines 1 8 added test button description ...

Page 36: ...34 Installation guide DEiMiC ONE MASTER v1 8 Installer notes ...

Page 37: ...35 Installation guide DEiMiC ONE MASTER v1 8 Installer notes ...

Page 38: ... to the producer service 5 The equipment under the warranty should be delivered to the place of purchase 6 All services under the warranty are done in DEiMiC SP z o o company service only 7 The warranty does not cover batteries and device defects caused by a reasons not dependent on the producer b mechanical defects c usage not comply with the device instruction or with the device destination d ra...

Page 39: ...PRODUCT REMARKS fills the seller or the installer in case of purchasing the device after price reduction Signature Stamp of the producer or seller Repair date Repair description ...

Page 40: ... 2015 DEiMiC ...

Reviews: