The default IP address is 192.168.1.99 port 502.
DT-FogControl
also allows you to check the status of the device and the wire inputs, as well as the
basic and special programming set physically through the DipSwitches.
DT-MultiFogControl
is responsible for monitoring simultaneously the operating status of several
Fogs Generators (even in different geographical sites).
Both software can be requested free of charge by making a request
(complete with social data) at the following address
IP ADDRESS AND PASSWORD RESET PROCEDURE
1. Disconnect ARM and FOG
2. Switch the appliance off completely
3. Note down the DIP-SWITCH configuration
4. Turn all DIP-SWITCH OFF
5. Remove the Jumper from BUZZ (J3)
6. Place the Jumper on J2
7. Set the DIP-SWITCH No. 10 to ON
8. Supply the appliance
9. Set the DIP-SWITCH no. 1 to ON
10. Switch the appliance off again
11. Remove the Jumper from J2 and replace it on BUZZ (J3)
12. Restore the DIP-SWITCH as noted down before (point 3)
13. Supply the appliance