FUNCTIONAL DESCRIPTION IN SHORT
BURNER MANAGEMENT:
The burner is activated only when the machine is ARMED and this can happen only by activating
the "ARM" input on the CPU board or by using the "Preheating" special function which maintains
the operating temperature at 50% during disarming (this to speed up the reset phase especially for
the DT-400Lan model).
The 100% burner ignition will be inhibited if the time block is active, programmable through the
Sw DT-FogControl (checkout the instruction manual).
When the appliance is armed (ARM), the heating resistance is activated.
The resistance will only be deactivated after reaching 100% of the operating temperature.
When the temperature drops below 97% it will reactivate for a few seconds.
SHOT MANAGEMENT:
The shot is inhibited when:
- the appliance is unarmed.
- the burner temperature is lower than that needed to dispense dry and quality fog.
- The forced pause phase is active (used to avoid excessive shots in a room already
saturated with fog).
- The "Safe Firing" function is active.
- Liquid level is ZERO.
The shot has a configurable duration (60 seconds default).
At the end of the shot the system will ignore any further firing request for the set standby
time (forced pause).
At any time the firing phase can be interrupted, DISARMING the appliance.
ETHERNET NETWORK CONNECTIVITY:
The DT-x00Lan series devices have been designed to be monitored and programmed remotely
using the DEFENDERTECH "DT-FogControl" and "DT-MultiFogControl" software.
DT-FogControl is responsible for programming:
The IP address and port
Date and time
The Time block function
Download the technical log of the events
Liquid Level Reset
Reset Fault messages (Note. If the fault is persistent, the signal will continue)
Perform the "shot" (if there are the necessary technical conditions)
Changing the passwords of the 3 access levels