background image

5  Installation 

 

Dedrone 

10 

 

IM-Inst-DT2536en 

5.1.4

 

Power Supply, Cable Requirements and Required Tools 

Power Supply 

The Multi Sensor does not need any additional power supply connection. The power supply is 
provided by the patch cable over active PoE+ (802.3at). 

 

Make sure, that your network has activated 

active PoE+ (802.3at)

 

We recommend installing additional overvoltage protection between the sensor and the 
switch. 

Cable Requirements 

Type 

Cat-6 Patch Cable 

Recommendation:

 Cat-7 Patch Cable 

Maximum Length 

100 m (328 ft) 
For longer distances a PoE extender is required 

External Diameter 

3.5 mm – 7.5 mm 

 

For a weather resistant connection to the Multi Sensor, it is necessary to crimp the supplied 
environmentally sealed Ethernet crimp connector to the patch cable (see 5.2 Cable Preparation 
(Crimp),
 page 12). 

Required Tools 

 

drilling machine 

 

screwdriver 

 

suitable screws for the underground 

 

depending on the mounting location a ladder or lift truck 

 

crimping tool. For an environmentally sealed connection to the Multi Sensor, it's necessary 
to crimp the supplied connector to the patch cable. 

 

hex key: size 4 mm 

 

wrench: size 13 mm 

 

 

Summary of Contents for Multi Sensor 2.5

Page 1: ...Version 2 6 IM Inst DT2536en ENGLISH INSTALLATION Manual Multi Sensor 2 5 ...

Page 2: ...mbH Internal reproduction used solely for the purpose of product evaluation or other proper use is allowed and does not require prior approval Copyright This manual is the intellectual property of Dedrone GmbH and is protected by copyright All rights reserved Dedrone GmbH Miramstraße 87 34123 Kassel Germany Fon 49 561 861799 0 Fax 49 561 861799 111 Email info dedrone com 2017 Dedrone GmbH All righ...

Page 3: ... Preparation Crimp 12 5 3 Installation with DT Wall Mount 13 5 4 Installation with DT Pole Mount 14 6 Configuration 15 6 1 Overview Ports Multi Sensor 15 6 2 Overview Ports DroneTracker Server 15 6 3 Integrate Multi Sensor in Your Network and Login to DT Control Center 17 7 Update 19 7 1 Update Process 19 7 2 Update the DroneTracker Server with Internet Connection 19 7 3 Update a DroneTracker Syst...

Page 4: ...al and private use The Multi Sensor is not a security camera to observe the ground The Multi Sensor is suitable for indoor and outdoor use Use this product only in accordance with the information provided in the enclosed documentation and with the locally applicable legal standards and directives Any other application may cause personal injury or property damage Do not use the Multi Sensor for the...

Page 5: ...rvicing to qualified service personnel Such damages can be the patch cable is damaged an object has fallen on the device the device has been dropped or its enclosure has been damaged the device does not operate normally when the user follows the operating instructions correctly Adjust only those controls specified in the operating instructions Improper adjustment of other controls may cause damage...

Page 6: ...amera B Multi Sensor E DT Mounting Plate C HD Camera F DT Heat Sink With the interacting sensors the Multi Sensor is able to detect all kind of civil drones Based on multiple parameters such as noise shape and movement patterns the detection rate is optimal Depending on the environmental weather conditions drone type and drone size the detection rate varies significantly In case of a drone alert t...

Page 7: ...e scope of delivery are included If any items are missing notify your Dedrone Partner Do not use this product if any component appears to be damaged Please contact Dedrone in the event of damaged goods 1 x Multi Sensor 1 x DT Wall Mount and DT Pole Mount 2 x Straps 1 x Bag with 2x screws Torx M5 4x flat washer 2x nuts 1 x Bag with 1x environmentally sealed Ethernet crimp connector 1x RJ45 Plug 1 x...

Page 8: ... Ensure that the location has the appropriate clearance from power and lightning conductors in accordance with NEC725 and NEC800 CEC Rule 16 224 and CEC Section 60 Do not install the device near the following object Any excessive heat sources Any overhead power lines power circuits or electrical lights or where there is a chance of electrical discharge Note the properties of each Multi Sensor This...

Page 9: ...dware sold separately under all expected conditions of load vibration and temperature 5 1 3 Mounting Orientation The Multi Sensor is designed for installation like the picture below facing away from a vertical surface The maximum inclination is 28 to the vertical Ensure that the rain and sun cover of the camera is orientated above the camera Correct and incorrect mounting orientations ...

Page 10: ...commendation Cat 7 Patch Cable Maximum Length 100 m 328 ft For longer distances a PoE extender is required External Diameter 3 5 mm 7 5 mm For a weather resistant connection to the Multi Sensor it is necessary to crimp the supplied environmentally sealed Ethernet crimp connector to the patch cable see 5 2 Cable Preparation Crimp page 12 Required Tools drilling machine screwdriver suitable screws f...

Page 11: ...Wall Mount or the DT Pole Mount To mount the Multi Sensor with another mounting equipment note the following requirements for the mounting equipment licensed for outdoor use safe and stiff load of 8 4 lb 3 8 kg matching for the holes of the DT Mounting Plate Dimensioning of the holes of the DT Mounting Plate ...

Page 12: ...the braid and foil 4 Fold back the braid and foil over the cable jacket Note 25 mm 1 of free conductors are needed 5 Unravel the conductors sort the conductors in the required wiring standard 568 A or 568 B and push the conductors all the way in the plug The required wiring standard can be checked on the previous cut off RJ45 plug Position 568 A 568 B 1 White Green White Orange 2 Green Orange 3 Wh...

Page 13: ...nt and the contact field for the DT Heat Sink shows to the front Put a flat washer between the screw head and the DT Mounting Plate Put a lock washer between nut and DT Wall Mount 4 Position the Multi Sensor carefully on the DT Mounting Plate and screw down the 4 screws 5 Adjust the Multi Sensor in the desired angle Note the maximal inclination of 28 to the back 6 Connect the crimped patch cable s...

Page 14: ...ween the screw head and the DT Mounting Plate Put a lock washer between the DT Pole Mount and the nut and screw it down 3 Run both straps through the slashes of the DT Pole mount 4 Hold the DT Pole Mount at the desired height of the pole lay the straps around the pole put the strap in the slash under the screw of the strap and tighten it appropriately 5 Position the Multi Sensor carefully on the D...

Page 15: ...oad of updates communication with Cloud api dedrone com 80 8000 and 31852 TCP configurable Notifications configurable configurable TCP UDP DNS DNS via DHCP 53 UDP NTP Time sync pool ntp org 123 UDP SNMP traps Notifications configurable 162 UDP OpenVPN Dedrone Service Access access dedrone com 1194 6 2 Overview Ports DroneTracker Server Incoming Protocol Service Function Port TCP SSH Dedrone Servic...

Page 16: ...Download of updates communication with Cloud api dedrone com 80 8000 and 31852 TCP configurable Notifications configurable configurable TCP UDP DNS DNS via DHCP 53 UDP NTP Time sync pool ntp org 123 UDP SNMP traps Notifications configurable 162 UDP OpenVPN Dedrone Service Access access dedrone com 1194 ...

Page 17: ...Set up a DroneTracker Server Requirements Multi Sensor is installed Multi Sensor is connected to the network the power supply is working and the button at the Multi Sensor illuminates blue the IP address of the Multi Sensor is known Procedure 1 Start your web browser For an optimal use Dedrone recommends Chrome or Firefox 2 Enter the IP address of the DroneTracker Server in the address field of yo...

Page 18: ...6 Configuration Dedrone 18 IM Inst DT2536en For further information consult chapter First Steps of the integrated online help in the DT Control Center ...

Page 19: ...date sensors 3 If used update Analytics Servers 7 2 Update the DroneTracker Server with Internet Connection Requirements Existing access to DedroneCloud Configured Dedrone Account Login credentials for the user interface DT Control Center Update DroneTracker Server 1 Login to the DT Control Center 2 Choose menu OPTIONS Software Version 3 Choose Check for Updates The window Software Update appears ...

Page 20: ...fy that the string Offlinemode 1 is included in file etc apt cacher ng acng conf 3 Stop the service apt cacher ng root service apt cacher ng stop 4 Clean actual software repository root rm r var cache apt cacher ng 5 Unpack the tarball as user root and set correct permissions root tar xzf the_update_repository tgz C var cache apt cacher ng root chown R apt cacher ng apt cacher ng var cache apt cac...

Page 21: ...update the sensors are getting disconnected and reconnected Some short System Messages show connection process 7 5 Update Analytics Servers If external sensors are used in the DroneTracker System e g IP Cameras radar or jammer one or more Analytics Servers are required 1 Login to the DT Control Center 2 Choose menu OPTIONS Software Version 3 Choose Update x Server s The button is getting grey and ...

Page 22: ...damages the housing The wrong cleaner can damage the housing of the Multi Sensor Never use glass cleaner or other solvent cleaner to clean the Multi Sensor Use solvent free plastic cleaner to clean the Multi Sensor 10 Disposal Dispose the Multi Sensor at the end of its service life in accordance with the disposal regulations for electronic waste which apply at the installation location at that tim...

Page 23: ...ction Rating IP54 Range up to 500 m 1640 ft Internal Memory 256 GB Connectivity Fast Ethernet 100 Mbit s Power Supply active PoE 802 3at Power Consumption 20 W typ Audio Stereo Audio Audible Sonic Ultrasonic Spectrum 0 96 kHz Video 1080p HD Camera 11 22 5 60 or 85 Infrared Near Infrared HD Camera Wi Fi Omnidirectional Scanning 2 4 GHz ISM band Mounting with Back Plate VESA 75 VESA 100 48x60 130x13...

Page 24: ... AES SRP Protocols TCP UDP Alarm Notifications via user interface SMS email Network Message TCP IP SNMP Pushover net Network Services Incoming SSH HTTP SNMP Network Services Outgoing HTTP DNS NTP SNMP traps OpenVPN Tracking stand alone sensor or series combined sensors Integration via LAN in existing infrastructure Updates via cloud Day Night Mode automatic switching ...

Page 25: ...Dedrone 12 Overview Sensor Installations IM Inst DT2536en 25 12 Overview Sensor Installations Position and Orientation Lens Mac Address Serial No ...

Page 26: ...DRONE DETECTION TECHNOLOGY Dedrone GmbH 49 561 861799 0 Miramstraße 87 info dedrone com 34123 Kassel www dedrone com ...

Reviews: