5 Installation
Dedrone
8
IM-Inst-DT2536en
5
Installation
5.1
Select the Mounting Place
5.1.1
Mounting Location
Select a secure installation location and mounting position for the device. Ideally, this is a
location where the device cannot be interfered with, either intentionally or accidentally.
Sonic and ultrasonic noise
can disturb or disable the acoustic detection.
Mount the Multi Sensor as far away as possible from any source of noise, e.g.:
•
Fans
•
Radiators
•
Converters
•
Speakers
•
Electrical motors
•
Capping power supplies
•
Trees (moving leaves producing ultrasonic noise)
Ensure that the location has the appropriate clearance from power and lightning conductors,
in accordance with NEC725 and NEC800 (CEC Rule 16-224 and CEC Section 60). Do not install
the device near the following object:
•
Any excessive heat sources
•
Any overhead power lines, power circuits, or electrical lights, or where there is a chance
of electrical discharge.
Note the properties of each Multi Sensor.
This is needed for service and for correct
configuration. You can find all information on the type label on the backside of the
Multi Sensor.
We recommend to use the table in this manual (see chapter 12 Overview
Multi Sensor Installations, page 25). The following information is important:
•
Serial Number
•
MAC Address Video
•
MAC Address Audio
•
Type of Lens
•
Position and Orientation