5 Installation
Dedrone
12
IM-Inst-DT2536en
5.2
Cable Preparation (Crimp)
For a weather resistant connection to the Multi Sensor, it is necessary to crimp the supplied
environmentally sealed Ethernet connector to the patch cable. The used patch cable must
comply the defined cable requirements (see 5.1.4 Power Supply, Cable Requirements and
Required Tools, page 10).
Procedure:
1
Cut the RJ45 plug off the laid cable. Keep the cut off plug, to check the wiring
standard later.
2
Thread the gland nut and the connector body
on to the cable.
3
Remove the cable jacket carefully. Therefore take care not to damage the braid and
foil.
4
Fold back the braid and foil over the cable jacket.
Note: 25 mm (1”) of free conductors are needed.
5
Unravel the conductors, sort the conductors in
the required wiring standard (568-A or 568-B)
and push the conductors all the way in the plug.
The required wiring standard can be checked on
the previous cut-off RJ45 plug.
Position
568-A
568-B
1
White/Green White/Orange
2
Green
Orange
3
White/Orange White/Green
4
Blue
Blue
5
White/Blue
White/Blue
6
Orange
Green
7
White/Brown White/Brown
8
Brown
Brown
6
Crimp the RJ45 plug with the crimping tool.
7
Push down the latching clip of the plug and press the connector body all the way to
the stop over the RJ45 plug.
8
Put the bigger gland nut over the connector body and screw down the small gland
nut on the connector body.
1
Front Face View