Manual 

Object Detector 

S-SW-8

 

02-22-2021 

 

 

1

 

Function, Construction and Purpose .................................................... 2

 

2

 

Evaluation Unit ........................................................................................ 3

 

2.1

 

Electrical Connections .......................................................................................... 3

 

2.2

 

Sensor Electrodes ................................................................................................ 4

 

2.3

 

Configurations and Indication elements ................................................................ 5

 

2.3.1

 

SW1: Set sensitivity (relay switching point) & start calibration (SW2-2 OFF) ..................... 5

 

2.3.2

 

SW2: Setting of functional properties .................................................................................. 5

 

2.3.3

 

Indication Elements .............................................................................................................. 6

 

2.4

 

Installation ............................................................................................................ 6

 

2.4.1

 

Starting manual adjustment - switch SW2-2 to "OFF" ......................................................... 6

 

2.4.2

 

Sensitivity setting (relay switching point) ............................................................................. 6

 

2.5

 

Technical Data ...................................................................................................... 7

 

3

 

Montage & Cabling ................................................................................. 8

 

3.1

 

System arrangement ............................................................................................ 8

 

3.2

 

Electrical connections ........................................................................................... 9

 

4

 

Installation ............................................................................................... 9

 

 

 

 

 

 

Warning! Advisement about the difference between S-SW-8 and S-SW-3:  

Differently of S-SW-3, the first time that S-SW-8 starts operation, an adjustment must 
be triggered with empty sensor detection area. To do this, press SW1 at least 5 sec-
onds,  until  the  LED4  lights  up  red  (calibration  started).  The  calibration  process  is 
completed when LED1 flashes green. Only after that objects can enter the detection 
area (relay switches on) or the sensitivity can be changed. We recommend using the 
automatic sensitivity adjustment. 

 

Summary of Contents for S-SW-8

Page 1: ...manual adjustment switch SW2 2 to OFF 6 2 4 2 Sensitivity setting relay switching point 6 2 5 Technical Data 7 3 Montage Cabling 8 3 1 System arrangement 8 3 2 Electrical connections 9 4 Installation...

Page 2: ...the sensitivity is set appropriately the presence of the new objects is detected A potential free contact relay turns ON OFF according to the IN OUT movement of objects over the sensing area the swit...

Page 3: ...Connections Con nector Pin Connection X1 1 24 VAC DC Supply Voltage Both polarity accepted 2 3 PE Reference Potential Connected to the earth X2 1 C Relay common contact 2 NO Relay normally open contac...

Page 4: ...of the evaluation unit via the shield of the coaxial cable Montage structure C The design of the mounting structure depends on the conditions at the installation place It must be made of conductive ma...

Page 5: ...switch on point occupied and the switch off point free for the relay The sensor signal level for the switch ON point is stronger than the switch OFF point A larger hysteresis means that the switch ON...

Page 6: ...ves the reference value of the system The sensor electrodes must be free when performing a new adjustment No objects or person may be near the sensor electrodes SW2 2 OFF Memory OFF After power ON the...

Page 7: ...n 2 5 Technical Data Parameter Sim Condition min tip max Unit Supply Voltage UV AC DC 18 24 30 V Operation Power IV 18V UV 30V 3 W Environment Tempera ture TF In operation 15 20 55 C TL Storage 20 60...

Page 8: ...ts to be detected This ensures safe switching behavior The evaluation unit should be installed near the sensor electrodes The sensor line coaxial cable between the evaluation unit and sensor electrode...

Page 9: ...e 5 Connect the reference potential of the evaluation unit X1 3 direct to the earthed mounting struc ture 6 Connect the supply voltage 24VAC DC to the evaluation unit X1 1 X1 2 7 First operation By th...

Page 10: ...timum sensitivity for the working object is set LED2 confirms the process by flashing briefly 2 Manual Relay OFF LED5 OFF Rotate the switch SW1 clock wise until the relay switches ON plus three more p...

Reviews: