Installing the outside sensor
4.9.1.
Choice of the location
It is important to select a place that allows the sensor to measure the
outside conditions correctly and effectively.
Advised positions:
4
on one face of the area to be heated, on the north if possible
4
half way up the wall in the room to be heated
4
under the influence of meteorological variations
4
protected from direct sunlight
4
easy to access
A
Recommended position
B
Possible position
H
Inhabited height controlled by the sensor
Z
Inhabited area controlled by the sensor
Positions to be avoided:
4
masked by a building element (balcony, roof, etc.)
4
close to a disruptive heat source (sun, chimney, ventilation grid,
etc.)
4.9.2.
Connecting the outside sensor
Mount the sensor using the screws and dowels provided.
8800N001-C