4.5
Contents of the package
The boiler is delivered in a package comprising:
A wall-hung gas boiler
A bracket for fastening the boiler to a wall
A flue gas fitting
A paper template
An installation and service manual
A user manual
A condensate drain pipe
Dowel/screw kit for fastening the boiler to a wall
4.6
Accessories & options
All accessories and options are available by consulting the De Dietrich price list.
5 Before installation
5.1
Installation standards and rules
The boiler must only be installed by a qualified installer in accordance with local and national regulations.
Installation must be performed exclusively by a qualified technician in accordance with Ministerial Decree no. 37 of 22 January
2008 as subsequently amended and supplemented. The installation, operation and maintenance of the system must be carried
out in accordance with current legislation relating to thermal installations. In addition, where relevant, the following provisions
must be observed:
Ministerial Decree of 12 April 1996 as subsequently amended and supplemented. - Approval of the technical rules on fire
prevention for the design, construction and operation of thermal installations supplied by gaseous fuels;
The gas supplier.
The installation must be carried out according to best industry practice; using and complying with the UNI and CEI installation
standards guarantees compliance with such practice. In particular, the following standards/decrees should be followed:
UNI 7129
UNI 7131
UNI 8065
CEI 64-8
CEI 64-9
Ministerial Decree of 26 June 2015
This boiler can be installed outdoors in a partially protected location. A partially protected location is one in which the boiler is
not exposed to the direct action of atmospheric precipitation (rain, snow, hail, etc.).
5.2
Installation requirements
Warning
The following technical instruction notes are intended for installers.
5.2.1
Power supply
Supply voltage
230 V ~ / 50 Hz
en
5 Before installation
160
INIDENS
7804841 - 02 - 20012022
Summary of Contents for INIDENS 20/24 MI
Page 5: ...1 2 3 4 5 1 2 3 4 1 2 3 mm EN 60335 1 0 8 1 5 2 1 bg 7804841 02 20012022 INIDENS 5...
Page 6: ...De Dietrich 1 3 1 3 1 1 3 2 1 3 3 2 2 1 2 2 bg 2 6 INIDENS 7804841 02 20012022...
Page 24: ...13 BO 0000071 5 1 2 3 4 LIFT 10 6 7 8 9 b a LIFT 6 6 1 6 2 bg 6 24 INIDENS 7804841 02 20012022...
Page 26: ...16 BO 0000279 40 6 3 30 Nm 6 3 1 6 3 2 1 2 1 2 bg 6 26 INIDENS 7804841 02 20012022...
Page 42: ...7 7 1 28 7 2 1 2 3 4 5 1 0 1 5 6 7 8 9 7 3 60 mbar 6 kPa bg 7 42 INIDENS 7804841 02 20012022...
Page 72: ...1 2 3 4 5 6 7 8 9 10 bg 13 72 INIDENS 7804841 02 20012022...
Page 76: ...1 2 3 4 5 1 2 3 4 1 2 3 mm EN 60335 1 0 8 bar 1 5 2 bar el 1 76 INIDENS 7804841 02 20012022...
Page 77: ...De Dietrich 1 3 1 3 1 1 3 2 1 3 3 2 2 1 2 2 2 el 7804841 02 20012022 INIDENS 77...
Page 95: ...59 BO 0000071 5 1 2 3 4 LIFT 10 6 7 8 9 b a LIFT 6 6 1 6 2 6 el 7804841 02 20012022 INIDENS 95...
Page 97: ...62 B BO 0000279 111 6 3 30 Nm 6 3 1 6 3 2 1 2 1 2 6 el 7804841 02 20012022 INIDENS 97...
Page 131: ...10 3 6 1 2 3 4 5 87 BO 0000208 3 A 2 4 1 5 10 el 7804841 02 20012022 INIDENS 131...
Page 143: ...1 2 3 4 5 6 7 8 9 10 13 el 7804841 02 20012022 INIDENS 143...
Page 348: ...it 13 Smaltimento 348 INIDENS 7804841 02 20012022...
Page 349: ...13 Smaltimento it 7804841 02 20012022 INIDENS 349...
Page 350: ...it 13 Smaltimento 350 INIDENS 7804841 02 20012022...