Alarms and Presets
Alarms and Presets
Camera XX
Detected
Not Detected
Telemetry protocol None
BBV, Pelco, DM, (serial telemetry)
Preset
Mod/Aux
Contact
Input
>
--
Aux
01
N/O
>
--
--
Camera XX
The currently selected camera number is displayed, along with its status -
detected or not detected. Press a camera key to select a camera to configure
alarms and presets for that camera.
Telemetry protocol
Select the telemetry protocol for the camera; BBV, Pelco, DM, or the serial
telemetry dome selected in the ‘System Options’ menu page.
BBV and Pelco is Coaxial telemetry, if you are using Pelco serial telemetry it is
displayed as ‘Pelco-P’. DM telemetry is twisted pair DTMF telemetry (using a
TAD3) or 485-Bus telemetry.
Note:
Tours are not available when using Pelco coaxial telemetry.
Notes for JVC domes:
There are two types of serial telemetry for JVC domes:
type 1 and type 2. Select the correct type to correspond to the model number
from the list below:
Type 1
Type 2
TK-C675E
TK-C675BE
TK-C675U
TK-C675BU
TK-C553E
Preset
If the camera has telemetry presets configured, these can be recalled when
an alarm is triggered. Enter the preset number from 00 to 99 for the selected
alarm contact.
Mod/Aux
Alarm contacts can be connected to the auxiliary alarms on the rear of the unit,
or using an external alarm module. If an alarm module is to be used, select the
address of the module being used, 1 to 16. Up to 16 alarm modules can be
connected to the 485-bus network.
Contact
Each alarm module has 16 alarm inputs, each input can be used by any camera
or multiple cameras.
Input
Select whether the alarm contact on the alarm device is normally open (N/O)
or normally closed (N/C).