SMALL PIPING CONNECTIONS FOR “RWA” PUMPS
7
ALLOWABLE PIPING LOADS FOR RWA2096, RWA4166 AND RWA4206 PUMPS
MAXIMUM FORCES ON FLANGES
FOR SUCTION FLANGE
+/-Fx
≤
200 LBS./NOM.IN.
≤
1.2W
+/-Fy
≤
130 LBS./NOM.IN.
≤
0.6W
+/-Fz
≤
160 LBS./NOM.IN.
≤
1.0W
Fr = (Fy
2
+ Fz
2
)
1/2
≤
2000 LBS
FOR DISCHARGE FLANGE
+/-Fx
≤
160 LBS./NOM.IN.
≤
1.3W
-Fy
≤
200 LBS./NOM.IN.
≤
1.2W
+Fy
≤
100 LBS./NOM.IN.
≤
0.5W
+/-Fz
≤
130 LBS./NOM.IN.
≤
1.0W
Fr = (Fx
2
+ Fz
2
)
1/2
≤
2000 LBS
WHERE
F = FORCE IN POUNDS
Fr = RESULTANT FORCE
W = WEIGHT OF PUMP ONLY, IN POUNDS
Wt.-Lbs.
M
X
M
Y
M
Z
Pump Size
Pump Only lb. ft.
lb. ft.
lb. ft.
RWA2096
1X1
1
/
2
X6
105
278
192
91
RWA2096
1
1
/
2
X3X6
115
277
265
91
RWA2096
1X1
1
/
2
X8
125
278
132
91
RWA4166
1X3X8
1
/
2
195
690
340
725
RWA4166
1
1
/
2
X3 X8
1
/
2
220
690
340
725
RWA4166
2X3X8
1
/
2
245
690
340
725
RWA4166
3X4X8
1
/
2
270
725
295
600
RWA4166
4X6X8
1
/
2
310
785
320
600
RWA4166
1
1
/
2
X3X10
240
760
310
600
RWA4166
2X3X10
275
760
310
600
RWA4166
3X4X10
305
830
340
600
RWA4166
4X6 X10#2
345
950
340
600
RWA4206
4X6 X10#1
460
2300
1850
800
MAXIMUM MOMENTS APPLIED TO A PUMP ON A FULLY BOLTED AND GROUTED BASEPLATE. LOADS ARE TO BE
APPLIED ONLY THROUGH THE SUCTION AND DISCHARGE FLANGES.
Maximum allowable forces and moments
calculated from these force equations or the
tabulated moment tables are those resulting in
a maximum of .010 inch movement of the
shaft measured at the shaft coupling when the
pump is mounted on its baseplate and that
baseplate is fully bolted to a properly
designed foundation and is fully grouted in
place. For a full discussion see API Standard
610, 5
th
Edition.
DATA SHEET #1198H
VAPOR EXHAUST
PUMPAGE LEAK
PROTECTION
VAPOR
ELIMINATOR
SEAL VENT PLUG
CASING DRAIN PLUG
GREASE RELIEF PLUG
(NOT ON RWA2096)
GLAND VENT PLUG
DISCHARGE
FLANGE
SUCTION
FLANGE
Fy
Fy
Fz
Fz
Fx
Fx
Mx
My
Mz