background image

EN-3

2  PRODUCT DESCRIPTION

2.1  Description

A family of automatic hydraulic traf

fi

 c bollards is identi

fi

 ed with the name ROCK. The cylinder is driven by a hydraulic unit positioned 

inside the same. The bollard has a manual safety release device which, if activated, allows the cylinder to be lowered, thus leaving the 
passage free in the case of emergencies and/or mains power failure.
The automatic lowering of the hydraulic unit, can only take place with the accessory solenoid valve (art. ROCK/EL not supplied) installed; 
in this case, the type of release can be selected by operating directly on the solenoid valve and activate, or not, the automatic lowering 
of the cylinder in the event of power failure.
The accompanying accessories are shown in the “PRODUCT ACCESSORIES” table (page I-9).

2.2  Content of the packaging

All the material is accurately controlled and inspected by the manufacturer before shipping.
On receipt of the bollard, make sure that it has not undergone damage during transport and that nothing has been tampered with or 
removed. If damage or missing parts are detected, immediately inform the carrier and the manufacturer, and produce photographic 
documentation. On receipt, during unpacking, dispose of the packaging components with reference to National Disposal Laws regarding 
solid waste.

2.3  Lifting and Transport

Suitable equipment must be used to lift and transport the bollard, with respect to work place safety regulations in force in the area of 
installation of the product.
The eye-bolts and the ropes must have capacity higher than the weight to be lifted, be in good working order and must have CE marking 
and respective certi

fi

 cation in force.

WARNING

 For transport of the bollard, vehicles are requires with minimum capacity higher than the weight declared for the same (the 

weight of the bollard is given on the identi

fi

 cation plate). Before beginning handling, check the ef

fi

 ciency of the lifting devices and 

their capacity. During bollard lifting and handling operations, all possible precautions must be taken in order to prevent hazardous 
movements, which could cause accidents or damage to the persons and/or materials and objects. Avoid sudden movements, which 
could lead to damage to the bollard.
The bollard must be handled by expert personnel.

3  TECHNICAL DATA

ROCK

ROCK/CABLE

Handling

Hydraulics

Rod out of the ground

700 mm

Cylinder diameter

275 mm

Standard cylinder material

Fe 360 steel

Cylinder treatment

Cataphoresis and black polyester powder paint

Ascent time

~ 6 sec

Descent time (standard)

~ 5 sec

Rapid descent time (via solenoid valve and power 
supply failure)

~ 1,5 sec

Max. N°. manoeuvres in 24 hours

300 (with art. ROCK/EL solenoid valve)

2000 (without solenoid valve *considering a temperature of 20÷22°C)

Retro-re

fl

 ective strip

50 mm

Manual lowering manoeuvre

Mechanical release on hydraulic circuit

Shock resistance

29 kJ

 with anchor bolts - 

40 kJ

 with additional reinforcement

Resistance to breakthrough

29 kJ

 with anchor bolts - 

138 kJ

 with additional reinforcement

Connection cable

/

15 m 7Gx1,5 + 10x0,5

Warning:

 In order to prevent operating problems inside the plant, the connection cables 

must have maximum length of 80 metres. Any cable joints must be made perfectly and inside 
junction boxes.

Operating temperature

-15 ÷ 50 °C

-25 ÷ 50 °C (with art. ROCK/RE heater)

Anti-rising safety device

Adjustable with pressure switch

Product weight

130 kg

Power supply voltage

230 V ~ ±10% (50/60 Hz)

Absorption

400 W

Protection rating

IP 67

Condenser

12,5 

μ

F

Motor thermal monitoring

130 °C

Summary of Contents for ROCK

Page 1: ...otice d emploi et avertissements Hydraulischer Straßen Poller Bedienungsanleitung und Hinweise Disuasor de tráfico oleodinámico Instrucciones de uso y advertencias Dissuasor de tráfico hidráulico Instruções para utilização e advertências Hydrauliczny słupek blokady wjazdu Instrukcja montażu i użytkowania Гидравлический блокиратор движения Инструкции и предупреждения I6510XX Rev 01 20 06 18 ...

Page 2: ......

Page 3: ... have received proper training on safe use of the device and are aware of the dangers related to its use WARNING Do not allow children to play with the device the fixed commands or the ra dio controls of the system WARNING Product use in abnormal conditions not foreseen by the manufacturer may generate hazardous situations meet the conditions indicated in these instructions WARNING DEA System remi...

Page 4: ...arts not indicated by DEA System and or incorrect re assem bly can create risk to people animals and property and also damage the product For this reason always use only the parts indicated by DEA System and scrupulously follow all assembly instructions WARNING The compliance of the internal sensing obstacles device to requirements of EN12453 is guaranteed only if used in conjunction with motors f...

Page 5: ...tification in force WARNING For transport of the bollard vehicles are requires with minimum capacity higher than the weight declared for the same the weight of the bollard is given on the identification plate Before beginning handling check the efficiency of the lifting devices and their capacity During bollard lifting and handling operations all possible precautions must be taken in order to prev...

Page 6: ...ing withdrawals Lay the layer of geotextile 300 g on the compacted gravel Position a PVC pipe with diameter of 200 mm and length of 220 mm in the centre of the hole and ABOVE the geotextile the PVC pipe is necessary to channel the rain water Introduce concrete RCK45 type into the hole to a height of 200 mm making sure that the pipe remains in the centre and escapes by at least 20 mm Warning the co...

Page 7: ... metal pit up to ground level and successively connect the projecting part to the road surface Warning make sure that the concrete casting is vibrated using suitable equipment in away to adhere correctly to the walls of the metal pit and that the same remains above the ground level by at least 20 mm Fig 7 WARNING All piping must be positioned with full respect of regulations in force 4 6 Laying th...

Page 8: ... Yellow Yellow green Black 5 Black 4 Black 3 Black 2 Black 1 Blue 2 1 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 30 29 32 31 3 4 5 6 7 8 WARNING LOCK FLASH 230V MOT 1 MOT 2 34 33 WL FL 24V N F ENC_M2 ENC_M1 CON 1 CON 2 COM IN_1 COM IN_2 COM IN_3 COM IN_4 COM IN_5 COM IN_6 DISPLAY Serial N 000X XXXXXX ATTENTION The total absorption of the integrated standard components supplied with...

Page 9: ...lled using original accessories 5 ELECTRICAL CONNECTIONS Run the motor connections following the wiring diagrams WARNING For adequate electrical safety keep low safety voltage wires controls electro locks antenna auxiliary power clearly separate from 230V power wires minimum 4 mm in air or 1 mm via supplementary insulation placing them in plastic raceways and securing them with adequate clamps nea...

Page 10: ...ing position Check that the bollard is re blocked hydraulically after an eventual emergency manual release Fig 10 Check correct operation of the solenoid valve art ROCK EL not supplied and replace the component if necessary The bollard does not lower but remains low in closing position Check that there are no obstructions between the sliding ring and the cylinder Try to shake the cylinder to facil...

Page 11: ...р типового монтажа DEA System fornisce queste indicazioni che si possono ritenere valide per un impianto tipo ma che non possono essere complete Per ogni automatismo infatti l installa tore deve valutare attentamente le reali condizioni del posto ed i requisiti dell instal lazione in termini di prestazioni e di sicurezza sarà in base a queste considerazioni che redigerà l analisi dei rischi e prog...

Page 12: ...nante introduciendo uno 40 litros de agua y comprobando que el vaciado se realice en menos de 30 minutos Certificar se que o solo tenha uma boa capacidade drenante introduzindo cerca de 40 litros de água e verificando que o esvaziamento aconteça em menos de 30 minutos 8SHZQLý VLĘ ŮH JUXQW PD GREUĉ GROQRŒý RGSURZDG DQLD ZRG ZVWU NXMĉF RNRâR OLWUyZ ZRG L VSUDZG DMĉF F RSUyŮQLDQLH RGE ZD VLĘ Z F DVLH...

Page 13: ...olts Avec le barres Durch Krallen Con grapas Com EUDoDGHLUDV H ŒUXEDPL IXQGDPHQWRZ PL ǬǹǶDZǼǹȇǸǴ ǭǺǷǾǬǸǴ RQ DUPDWXUD GL ULQIRU R LWK DGGLWLRQDO UHLQIRUFHPHQW YHF l armature additionnelle Durch zusätzliche Armierungseisen Con VRSRUWH DGLFLRQDO RP DUPDomR DGLFLRQDO GRGDWNRZ P Z PRFQLHQLHP ǬǼǸǴǼǺǮǬǹǴDZǸ 4a ...

Page 14: ...0 mm Warning make sure that the height from the base of the cementing just performed is 1000 mm at the road surface Attention s assurer que la hauteur à partir de la base de la cimentation qui vient d être exécutée au revêtement de la route soit de 1000 mm Achtung Die Höhe von der Basis des gerade ausgeführten Betongusses bis zur Fahrbahnoberfläche muss 1000 mm betragen Atención asegúrese que la c...

Page 15: ...I 5 5 6a A x1 B x4 C x1 D x4 x40 x24 ...

Page 16: ...I 6 6b 6c ...

Page 17: ...hten Sie beim Absenken des Pollers darauf dass das Netzkabel und die Position des Schaltgehäuses nicht eingeklemmt oder angestoßen wird Atención durante la bajada de la estructura preste la máxima atención a no pellizcar el cable de alimentación y a la posición de la caja eléctrica Atenção ao abaixar a estrutura prestar a máxima atenção a não picar o cabo de alimentação e à posição da caixa elétri...

Page 18: ...I 8 10 9 ...

Page 19: ...столбиков ROCK Ø 273 мм h 700 мм ROCK RE 659060 Riscaldatore elettrico antigelo Antifreeze heater Dispositif de chauffage électrique antigel Frostschutzheizung Calentador eléctrico Aquecedor eléctrico anti gelo Podgrzewacz elektryczny zapobiegający zamarzaniu Антифриз Электрический подогреватель ROCK EL 659062 Solenoide per valvola discesa rapida Solenoid with power supply cable Electrovanne avec ...

Page 20: ...I 10 ...

Page 21: ...ease operation must sometimes be performed in emergencies All users must be instructed on the use of the release mechanism and the location of the release keys ROCK RELEASE MECHANISM All ROCK models have an unlocking system the working of this system is the following Unscrew the closure cap positioned on the head of the bollard Insert the relevant key supplied loosen anti clockwise by approx 1 tur...

Page 22: ...manual The object of the declaration described above is in conformity with the relevant Union harmonisation legislation Directive 2006 42 CE MD Directive Directive 2014 53 EU RED Directive Directive 2011 65 EU RoHS The following harmonised standards and technical specifications have been applied Title Date of standard specification EN61000Ͳ6Ͳ2 2005 EC 2005 EN61000Ͳ6Ͳ3 2007 A1 2011 EN301 489Ͳ1 v2 1...

Page 23: ......

Page 24: ...DEA SYSTEM S p A Via Della Tecnica 6 36013 PIOVENE ROCCHETTE VI ITALY tel 39 0445 550789 fax 39 0445 550265 Internet http www deasystem com E mail deasystem deasystem com BATCH ...

Reviews: