sliding gate 24V
sliding gate 230V
OPERATORS
CONFIGURATION
PARAMETERS
Selection
type
of
operators
•
005:
LIVI
5/24
•
006:
LIVI
8/24
•
007:
GULLIVER
/
REV
Unused
parameter
Unused
parameter
OPERATING PARAMETERS
Operators
speed
adjustment
during
slow
-down
while
opening
W
arning
(230V
only):
For
operators
without
encoder
,
speed
during
opening/closing
cycles
(100%)
and
slow
down
speed
during
opening/closing
cycles
(30%)
are
fixed
independently
from
set
values.
15%tot........................100%tot
Operators
speed
adjustment
during
the
stroke
while
opening
15%tot........................100%tot
Operators
speed
adjustment
during
the
stroke
while
closing
15%tot........................100%tot
Operators
speed
adjustment
during
slow
-down
while
closing
15%tot........................100%tot
Slow
down
duration
adjustment
while
opening
5%tot............................80%to
Slow
down
duration
adjustment
while
closing
5%tot............................80%tot
Operator
1
force
adjustment
while
opening
(if
=
100%
obstacle
detection
deactivated)
15%tot…...........................100%tot
Operator
n.1
force
adjustment
while
closing
(if
=
100%
obstacle
detection
deactivated)
15%tot…...........................100%tot
Unused
parameter
Unused
parameter
Automatic
closing
times
adjustment
(if
=
0
automatic
closing
deactivated)
0sec...................................255sec
Pedestrian
automatic
closing
time
adjustment
(se
=
0
pedestrian
automatic
closing
deactivated)
0sec...................................255sec
Pedestrian
stroke
duration
adjustment
5%tot…...........................100%tot
Pre
-flashing
time
adjustment
0sec…….10sec
Unused
parameter
Unused
parameter
Collectivity
function:
if
it
is
activated
it
deactivates
both
opening
and
closing
inputs
for
the
whole
duration
of
automatic
opening
and
closing
•
000:
“collectivity
function
”
deactivated
•
001:
“collectivity
function
”
activated
Ram
blow
function:
it
pushes
the
motors
closed
for
one
second
before
each
opening
movement,
so
as
to
ease
the
electric-lock
release
•
000:
“
ram
blow
”
deactivated
•
001:
“
ram
blow
function
”
activated
“Reversal”
mode
selectio
n
(during
the
manoeuvre
a
command
impulse
reverse
the
mouvement)
or
“step
by
step
”
(during
the
manoeuvre
a
command
impulse
stops
the
mouvement).
A
next
impulse
restart
the
operator
to
the
opposite
direction.
•
000:
“
reversal
function
”
•
001:
“step
by
step
function
”
PHO
TO
1
PHO
TO
input
functioning:
If=0:
photocell
enabled
while
closing
and
starting
when
the
gate
is
stopped;
if=1
photocells
are
always
enabled;
if=2
photocells
are
enabled
while
closing
only
.
When
enabled,
its
activation
provokes:
the
inversion
(while
closing),
the
stop
(while
opening)
and
prevent
the
starting
(when
gate
is
closed)
.
If=3-4-5,
the
operation
is
the
same
as
the
values
0-1-2
but
with
“close
immediately
”
enabled:
in
any
case,
during
the
opening
and/or
the
pause
time,
removal
of
a
possible
obstacle
causes
the
gate
automatically
closes
after
a
fixed
delay
of
5
sec.
•
000:
photocell
enabled
while
closing
and
when
gate
is
stopped
•
001:
photocells
always
enabled
•
002:
photocells
enabled
only
while
closing
•
003:
as
000
but
with
“close
immediately
”
enabled
•
004:
as
001
but
with
“close
immediately
”
enabled
•
005:
as
002
but
with
“close
immediately
”
enabled
PHO
TO
2