Thank you for choosing the products of Dandong Top Electronics Instrument (Group)-Co.,Ltd. 

This operation manual provides you with important information on installation, connection and 

commissioning as well as on maintenance, troubleshooting and storage. 

 

Please read it carefully before installation and commissioning and keep it as part of the product 

near the meter for easy reading. 

 

This manual can be downloaded by entering the version number at www.ddtop.com. 

If the instructions are not followed, the protection provided by the meter may be destroyed. 

 

Trademark, Copyright and Restriction Instructions 

Dandong Top Electronics Instrument (Group) Co.,Ltd.®, Dandong Top Pump Co.,Ltd.®,   

DDTOP® are registered trademarks of the company. 

 

The performance specifications of the meter are effective as of the date of publication and are 

subject to change without notice. Dandong Top Electronics Instrument (Group)Co.,Ltd. reserves the 

right to modify the products described in this manual at any time without prior notice. 

 

Quality Assurance 

Dandong Top Electronics Instrument (Group) Co.,Ltd. guarantees that all variable area flow meters 

have no defects in materials and manufacturing processes within one year from the date of delivery. 

During the warranty period, if the product returns with quality problems and the claim is 

determined by the manufacturer to be within the scope of warranty, Dandong Top Electronics 

Instrument (Group) Co.,Ltd. is responsible for repair or replacement of the buyer (or owner) free of 

charge. Dandong Top Electronics Instrument (Group) Co.,Ltd. is not responsible for the costs caused 

by improper use of equipment, labor claims, direct or subsequent damage and installation and use 

of equipment. In addition to the special written warranty certificate for certain products of Dandong 

Top Electronics Instrument (Group) Co.,Ltd., Dandong Top Electronics 

 

Summary of Contents for UHC Magnetic Level Gauge

Page 1: ...1 17 WWW DDTOP COM UHC Bb Remote Transmission MAGNETIC LEVEL GAUGE Operating Manual UHC Bb DT JS 1027 2018 A...

Page 2: ...and are subject to change without notice Dandong Top Electronics Instrument Group Co Ltd reserves the right to modify the products described in this manual at any time without prior notice Quality As...

Page 3: ...arranty Quality Dandong Top Electronics Instrument Group Co Ltd has passed the ISO9001 quality system certification The whole process of product production is strictly in accordance with the scope of...

Page 4: ...Product Descriptions 5 3 Technical Parameters 6 4 Outline Dimension Diagram 7 5 Unpacking and Inspection 8 6 Installation 8 7 Configuration 10 8 Precautions 15 9 Fault Analysis and Troubleshooting 16...

Page 5: ...onal standards codes and regulations Ensure that the equipment is installed in accordance with intrinsically safe or non flammable site operating procedures 1 2 Process leakage may cause serious injur...

Page 6: ...y or output to the control room through the output terminal to achieve long distance transmission of liquid level 2 3 Packaging Please take the packaging waste to a special recycling facility 2 4 Lift...

Page 7: ...40 80 Working Temperature 40 200 When T 150 the transmitter does not allow heat preservation Accuracy 5mm Power Inlet M20 1 5 female thread or as customer requirement Explosion proof Type Intrinsicall...

Page 8: ...product nameplate is consistent with the packing list information Figure 4 Figure 4 Product Nameplate 5 1 2 Check the quantity and material of each part against the packing list 5 2 Content of Inspect...

Page 9: ...point full scale of the remote transmission device marked at the factory and the O scale full scale of the on site indicator on the measuring tube are one to one correspondence and then fixed with a...

Page 10: ...lay a single variable or you can set the percentage and the main variable to cycle display and the effective digits of the decimal part can be set 0 1 2 3 4 decimal places The display mode is set by 4...

Page 11: ...n the 888 character in the lower left corner shows 1 17 it indicates that the transmitter is in the field configuration mode with menu rotation At this time you can input the initialization code modif...

Page 12: ...the key the up and down arrows on the left will light up indicating that the setting is saved 7 Press again to restart setting data 7 1 5 Key function code quick reference table When using button conf...

Page 13: ...n arrows on the left will light up Unit Setup 7 1 7 Range setting Set the lower limit of the range LRV Long press the key to enter the configuration mode first menu No 1 is displayed the up and down a...

Page 14: ...ation First adjust the PV value to the zero position Move the magnetic float to zero Switch the menu to No 11 and the LCD will display the current calibration position value at the same time and then...

Page 15: ...confirm and start the next digit setting and set other digits and decimal points in sequence When the up and down arrows on the left side light up the menu function setting is complete Compensation v...

Page 16: ...n the container etc Please refer to the instructions in the chapter 6 2 Installation Operation Process and 7 1 Electrical Wiring and remove the components in the reverse order of the operation steps 1...

Page 17: ...17 17 WWW DDTOP COM...