6 / 17
WWW.DDTOP.COM
1. Meter head assembly, converter circuit and LCD screen
2. Housing, protect the sensor circuit
3. Reed switch-resistance component, sensor circuit
2.2
Working Principle
The magnetic float in the measuring tube moves up and down with the fluid level or interface level
of the medium, so that the resistance value in the sensor circuit changes linearly, and then the
resistance value change is converted into a 4-20mA standard DC signal through the converter
circuit in the meter head assembly. LCD display or output to the control room through the output
terminal to achieve long-distance transmission of liquid level.
2.3
Packaging
Please take the packaging waste to a special recycling facility。
2.4
Lifting and Transportation
Please use quality lifting equipment and lifting straps, and pay attention to safety.
2.5
Storage
Storage temperature -20℃~40℃
Storage humidity≤40%
3.
Technical Parameters
3.1
Key Performance
3.1.1The remote transmission device has passed the national explosion-proof certification
Certification mark:Intrinsically safe Ex ia ⅡC T1~T5/T6 Ga;
Flameproof Ex d ⅡC T1~T5/T6 Gb
3.1.2 Executive standard
GB/T 25153-2010 Magnetic level gauge for chemical pressure vessel
JB/T 12957-2016 Magnetic level gauge
Summary of Contents for UHC Magnetic Level Gauge
Page 17: ...17 17 WWW DDTOP COM...