![DDK HFC3000II Instruction Manual Download Page 62](http://html1.mh-extra.com/html/ddk/hfc3000ii/hfc3000ii_instruction-manual_2460630062.webp)
Chapter 4 Installation
PAGE 4-26
4-7-3. Data Format (RS232C-1)
The fastening result data are output from the RS232C-1 interface at the end of fastening. The data
length of the fastening result data in ASCII format is 79 bytes (corresponding to 79 characters) per
single fastening operation. The format of the data output per Contorller is shown below.
・
Be careful because the decimal point differs according to tool model.
・
The output data of each item are indicated in a right-justified manner.
●
Output Data Format (in the case of ASCII format, with torque being indicated to 2 decimal places and the
rate is indicated to 3 decimal places)
When the fastening judgment is normal (ACCEPT)
COUNT No. :
Incremented by +1 at each fastening (stored even when power is shut down, reset in linkage
with erasing of 10,000 records)
ACCEPT COUNT:
Counted number of ACCEPT fastening judgments
(JDG: Judgment, OCR: Occurrence)
1 2 3 4 5 6 7 8 9 10 11 12 13 14
COUNT No.
ACCEPT
COUNT
CONTORLLER No.
WORK No.
30H 30H 30H 31H
30H 31H
30H 31H
20H
20H
30H 31H
20H
20H
0 0 0 1 0 1 0 1 0 1
15 16 17 18 19 20 21 22 23 24 25 26 27 28
PEAK TORQUE
JDG
OCR
FINAL ANGLE
JDG
OCR
31H 32H 2EH 33H 34H
20H
20H
20H
20H 31H 32H 33H
20H
20H
1 2 . 3 4 1 2 3
29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
FINAL TORQUE
JDG
OCR
RATE1
JDG
OCR
31H 32H 2EH 33H 34H
20H 20H 20H 30H 2EH 31H 32H 33H
20H 20H 20H
1 2 . 3 4 0 . 1 2 3
45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
RATE2
JDG
OCR
RATE3
JDG
OCR
30H 2EH 31H 32H 33H
20H 20H 20H 30H 2EH 31H 32H 33H
20H 20H 20H
0 . 1 2 3 0 . 1 2 3
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76
1ST TIME
JDG
OCR
2ND TIME
JDG
OCR
20H 31H 30H 2EH 30H
20H 20H 20H 20H 20H 32H 2EH 30H
20H 20H 20H
1 0 . 0 2 . 0
77 78 79
JDG CR
LF
4FH 0DH 0AH
O
TOTAL JUDGMENT
"O"(4FH): Fastening judgment
ACCEPT
[PEAK TORQUE] JUDGMENT
"H"(48H): HIGH REJECT
"L"(4CH): LOW REJECT
"A"(41H): ABNORMAL "S"(53H): STOP
"B"(42H): BYPASS
“R”(52H): RESET
“D” (44H): START OFF (Off operation by lever performed during
fastening)
The CAUSE OF REJECT OCR (OCR) is not set in the case of solitary
occurrence of "A," "B," "S," “R,” or “D.”
[FINAL TORQUE], [ANGLE], [RATE], [TIME] JUDGMENT
"H"(48H): HIGH REJECT
"L"(4CH): LOW REJECT
Caution
S0140185-H
Summary of Contents for HFC3000II
Page 17: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 S0140185 H...
Page 23: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 S0140185 H...
Page 28: ...Chapter 2 Specifications PAGE 2 6 Memo S0140185 H...
Page 29: ...Chapter 3 Part Names PAGE 3 1 Chapter 3 Part Names 3 S0140185 H...
Page 36: ...Chapter 3 Part Names PAGE 3 8 Memo S0140185 H...
Page 37: ...Chapter 4 Installation PAGE 4 1 Chapter 4 Installation 4 S0140185 H...
Page 69: ...Chapter 6 Description of Operations PAGE 6 1 Chapter 6 Description of Operations 6 S0140185 H...
Page 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 S0140185 H...
Page 163: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 S0140185 H...
Page 175: ...Chapter 9 External Interface PAGE 9 1 Chapter 9 External Interface 9 S0140185 H...
Page 206: ...Chapter 9 External Interface PAGE 9 32 Memo S0140185 H...
Page 207: ...Chapter 10 Warranty and Servicing PAGE 10 1 Chapter 10 Warranty and Servicing 10 S0140185 H...
Page 210: ...Chapter 10 Warranty and Servicing PAGE 10 4 Memo S0140185 H...
Page 211: ...Appendix List of Tool Models Appendix 1 Appendix List of Tool Models Appendix S0140185 H...
Page 214: ...Appendix List of Tool Models Appendix 4 Memo S0140185 H...
Page 215: ...Memo S0140185 H...