Chapter 9 External Interface
PAGE 9-19
●
Location of Handshaking Bits According to Size Configuration
Cyclic Cycles
Setting
1 Occupied Station
2 Occupied Station
3 Occupied Station
4 Occupied Station
1
24th bits / 18h
56th bits / 38h
88th bits / 58h
120th bits / 78h
2
24th bits / 18h
88th bits / 58h
152th bits / 98h
216th bits / D8h
4
56th bits / 38h
184th bits / B8h
312th bits / 138h
440th bits / 1B8h
8
120th bits / 78h
376th bits / 178h
632th bits / 278h
888th bits / 378h
(Location of “Initial Data Processing Request” and “Initial Data Processing Complete” Bits) “h” = hexadecimal
Below is an example of CC-Link configuration settings made by GX Developer software and how
memory is allocated. This configuration has 3 sets of
H
FC3000 controllers connected with 4 occupied
stations / 8 extended cyclic cycles. (I/O 896 Points, Message 72 Words)
Item
HFC3000 (System1)
HFC3000 (System2)
HFC3000 (System3)
CC-Link Station Number
1
5
9
Configured Size
(4 occupied stations
/ 8Cyclic cycles)
896 (880 useable)
896 (880 useable)
896 (880 useable)
EM-STOP
(First bit of PLC output)
Y100
Y480
Y800
Total Reject
(First bit of AFC3000 Output)
X100
X480
X800
Part ID message output to
AFC3000 Controllers
D4000
D4072
D4144
Fastening result message from
AFC3000 controllers
D1000
D1072
D1144
CC-Link Request address
X478
X7F8
XB78
CC-Link Enable address
Y478
Y7F8
YB78
In the case of the first AFC3000 System (1) (shown in the table above), the PLC program is set
so that
when the 888th (378h) bit (“Initial Data Processing Request”) in the (CC-Link Reserved) system area (X
area) is turned “ON”, the output at the 888th (378h) bit (“Initial Data Processing Complete”) of the system area
(Y area) is set “ON”.
Since the X/Y starting address of (System 1) is configured to start at X100 and Y100, this must be
added to the addresses and therefore (100h+378h) 478h is specified for the X area and the Y area as shown in
the PLC Logic diagram below to enable Station 1’s link.
(If the handshake is successful, 47B (100h + 378h + 3h) turns ON)
For Station 2’s link, the starting address (X/Y480) is added to the 888th (378h) bit for that station
which is address (480h + 378h) X/Y7F8.
(If the handshake is successful, 7FB (480h + 378h + 3h) turns ON)
For Station 3’s link, the starting address (X/Y800) is added to the 888th (378h) bit for that station
which is address X/YB78.
(If the handshake is successful, B7B (800h + 378h + 3h) turns ON)
PLC Logic example that would be required to enable the CC-Link in the three systems listed above
S0140185-H
Summary of Contents for HFC3000II
Page 17: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 S0140185 H...
Page 23: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 S0140185 H...
Page 28: ...Chapter 2 Specifications PAGE 2 6 Memo S0140185 H...
Page 29: ...Chapter 3 Part Names PAGE 3 1 Chapter 3 Part Names 3 S0140185 H...
Page 36: ...Chapter 3 Part Names PAGE 3 8 Memo S0140185 H...
Page 37: ...Chapter 4 Installation PAGE 4 1 Chapter 4 Installation 4 S0140185 H...
Page 69: ...Chapter 6 Description of Operations PAGE 6 1 Chapter 6 Description of Operations 6 S0140185 H...
Page 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 S0140185 H...
Page 163: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 S0140185 H...
Page 175: ...Chapter 9 External Interface PAGE 9 1 Chapter 9 External Interface 9 S0140185 H...
Page 206: ...Chapter 9 External Interface PAGE 9 32 Memo S0140185 H...
Page 207: ...Chapter 10 Warranty and Servicing PAGE 10 1 Chapter 10 Warranty and Servicing 10 S0140185 H...
Page 210: ...Chapter 10 Warranty and Servicing PAGE 10 4 Memo S0140185 H...
Page 211: ...Appendix List of Tool Models Appendix 1 Appendix List of Tool Models Appendix S0140185 H...
Page 214: ...Appendix List of Tool Models Appendix 4 Memo S0140185 H...
Page 215: ...Memo S0140185 H...