![DDK HFC3000II Instruction Manual Download Page 146](http://html1.mh-extra.com/html/ddk/hfc3000ii/hfc3000ii_instruction-manual_2460630146.webp)
Chapter 6 Description of Operations
PAGE 6-78
(11)
Gyro
D-No.006 Interrupt Operation During Fastening : Gyro Setup Enable ON
Set value: xxxx1x
By setting “1” for Gyro Settings Available ON as data No. 006 Interrupt Operation During Fastening, a
gyro pause operation is performed from after the detection of the 1st torque (D-No. 105) to the
attainment of the standard torque (D-No. 103).
* This setting is available for a P(pistol) type or a T type or a D(driver) type tool
(gyrosensor-incorporated type)
D-No.560 CW Swing Stop Angle
[deg]
Initial value: 30
D-No.570 CCW Swing Stop Angle
[deg] Initial value: 30
Setting range: 0~200
The upper limit angle of tool shaking by a reaction force, at which the operation is to be ended forcibly,
is set (always monitored).
When the angle of shaking of the tool exceeds this set value, the fastening operation is stopped
(Gyro Stop NG judgment).
【
Notes on gyro function
】
●
Since the controller version is V1.305 or higher, the above setting values are
enabled as the safety stop function even if the gyro function is disabled.
●
Please ON the start switch in the always state that the tool is still.
If fastening is started with the tool in operation, the angle measurement
becomes unstable and the safety stop function does not work normally.
D-No.561 CW Swing Pause Angle
[deg]
Initial value: 3
D-No.571 CCW Swing Pause Angle
[deg] Initial value: 3
Setting range: 0~200
The angle of tool shaking by a reaction force, at which the operation is to be paused, is set.
When the angle of shaking of the tool exceeds this set value, the fastening operation is paused.
After the pause, rotation is started again after the elapse of the pause time set as Data No. 563 or
573.
When the operation is paused, the detected angle value from the gyrosensor is reset to 0 degrees.
(Continued on next page)
105: 1st Torque
103: Standard Torque
561/571: CW(CCW) Swing Pause Angle
562/572: CW(CCW) Swing Stop Servo Lock Time
563/573: CW(CCW) Swing Motor Resume
Dwell Time
Gyro Detection Angle Origin (0°)
560/570:CW(CCW) Swing Stop Angle
▲Forced End
▲Completion of fastening
Pause
▲
Time
→
↑
Torque
↑
Angle
▲
Restart
Caution
S0140185-H
Summary of Contents for HFC3000II
Page 17: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 S0140185 H...
Page 23: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 S0140185 H...
Page 28: ...Chapter 2 Specifications PAGE 2 6 Memo S0140185 H...
Page 29: ...Chapter 3 Part Names PAGE 3 1 Chapter 3 Part Names 3 S0140185 H...
Page 36: ...Chapter 3 Part Names PAGE 3 8 Memo S0140185 H...
Page 37: ...Chapter 4 Installation PAGE 4 1 Chapter 4 Installation 4 S0140185 H...
Page 69: ...Chapter 6 Description of Operations PAGE 6 1 Chapter 6 Description of Operations 6 S0140185 H...
Page 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 S0140185 H...
Page 163: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 S0140185 H...
Page 175: ...Chapter 9 External Interface PAGE 9 1 Chapter 9 External Interface 9 S0140185 H...
Page 206: ...Chapter 9 External Interface PAGE 9 32 Memo S0140185 H...
Page 207: ...Chapter 10 Warranty and Servicing PAGE 10 1 Chapter 10 Warranty and Servicing 10 S0140185 H...
Page 210: ...Chapter 10 Warranty and Servicing PAGE 10 4 Memo S0140185 H...
Page 211: ...Appendix List of Tool Models Appendix 1 Appendix List of Tool Models Appendix S0140185 H...
Page 214: ...Appendix List of Tool Models Appendix 4 Memo S0140185 H...
Page 215: ...Memo S0140185 H...