M A N A G E M E N T C O N S O L E
Data Device Corporation
FC-76000 Manual
www.ddc-web.com
Rev A-01/10-0
24
Figure 17. Port Sub-menu
Figure 18 illustrates the screen dialog that occurs when a port is selected for
configuration. User entries are in bold.
Turning an unused port OFF will reduce the power consumption of the switch.
Turning a port off also disables the fiber-optic transmitter; no light will be emitted from
the Tx connector.
The B-B credit configures how many outstanding R_RDYs the switch will delay
before it stops transmitting frames out the specified port. The value selected here is
overridden by the explicit log-in value.
RT_TOV is the receiver-transmitter time out value (in milliseconds) and is used to
time events on the link such as Loss-of-Synchronization and expected responses to
link-level protocols. The value specified by the standard is 100 ms.
Figure 18. Set Port Dialog Screen
Port ON/OFF BB Credit RT_TOV
0 ON 8 100us
1 OFF 8 100ms
2 ON 15 100us
3 ON 1 100ms
4 ON 8 100ms
5 ON 8 100ms
6 ON 8 100ms
7 ON 8 100ms
8 ON 8 100ms
9 ON 8 100ms
10 ON 8 100ms
11 ON 8 100ms
12 ON 8 100ms
13 ON 8 100ms
14 ON 8 100ms
15 ON 8 100ms
Enter Port Number (0-15) ('q' to quit):
Enter Port Number (0-15) ('q' to quit):
0
Enter ON(1)/OFF(0) ('q' to quit):
1
Enter B-B Credit (0-15) ('q' to quit):
8
Enter RT_TOV mS(0) or uS(1) ('q' to quit):
0