O V E R V I E W
Data Device Corporation
FC-76000 Manual
www.ddc-web.com
Rev A-01/10-0
7
Table 2. FC-76000 Specification Table
PARAMETER
MIN
TYP
MAX
UNITS
ENVIRONMENTAL CHARACTERISTICS
(as per ANSI/VITA 47-2005) (cont’d.)
C-76161V2-300 (Forced Air Cooling) (cont
‟
d.)
Vibration Class: V1
5 Hz to 100 Hz (PSD) = 0.04 g²/Hz, 1 hr
per axis
Hz
Humidity
95% relative humidity for five 48 hr cycles
C-76161V2-200 (Forced Air Cooling)
VITA 47 Environmental Class EAC6
Operating Temp (inlet air): AC3
-40 - +70
°C
Minimum Required Air Volume Flow Rate (sea
level) at maximum inlet temperature
25
CFM
Non-Operating Temp: C3
-50 - +100
°C
Temperature Cycling: C3
-50 - +100, 500 cycles
°C
Vibration Class: V2
5 Hz to 100 Hz PSD increasing at 3
dB/octave, 1 hr per axis
100 Hz to 1000 Hz PSD = 0.04 g
2
/Hz, 1 hr
per axis
1000 Hz to 2000 Hz PSD decreasing at 6
dB/octave, 1 hr per axis
Hz
Hz
Hz
Humidity
95% relative humidity for five 48 hour
cycles
Shock Class
20g, 11 millisecond, half-sine shock
pulses in all three axes
g/ms
C-76161V2-C00 (Conduction Cooling)
VITA 47 Environmental Class ECC3
Operating Temp (alloable edge temp): CC3
-40 - +70
°C
Non-Operating Temp: C3
-50 - +100
°C
Temperature Cycling: C3
-50 - +100, 500 cycles
°C
Vibration Class: V3
5 Hz to 100 Hz PSD increasing at 3
dB/octave, 1 hr per axis
100 Hz to 1000 Hz PSD = 0.1 g
2
/Hz, 1 hr
per axis
1000 Hz to 2000 Hz PSD decreasing at 6
dB/octave, 1 hr per axis
Hz
Hz
Hz
Humidity
95% relative humidity for five 48 hour
cycles
Shock Class
40g, 11 millisecond, half-sine shock
pulses, all three axes
g/ms