The full DS-0 TSI mapping page is shown below:
LOOP AM3440-C === System Setup (MAP) === 13:47:09 12/01/2010
ARROW KEYS: CURSOR MOVE, TAB: ROLL OPTIONS
MAP NO: MAP_1
Target 8BDRA Source
Target PO/TS D SL/PO TS PO/TS D SL/PO TS PO/TS D SL/PO TS PO/TS D SL/PO TS
Slot : 3 ===== ========== ===== ========== ===== ========== ===== ==========
Port :
1 1 d 1 1 1
17 d
T.S. : 01
1 2 d 1 2 1
18 d
1 3 d 1 3 1
19 d
4 d 20 d
T.S.# : 1 5 d 21 d
Clear : No 6 d 22 d
d/v : d 7 d 23 d
8 d 24 d
9 d 25 d
Source 10 d 26 d
Slot : A 11 d 27 d
Port : 12 d 28 d
T.S. : 01 13 d 29 d
14 d 30 d
Confirm?Yes 15 d 31 d
16 d 32 d
Since 1+1 Port Backup was selected, host ports 1 & 5, 2 & 6, 3& 7, 4 & 8 are bridged. Host data
transmitted into either port and is received downstream via the Virtual Port time slots mapped to
the T1 DS-0s. Remote terminal responses are received on both of the paired ports.
In summary, follow these steps:
1. Select the backup type.
2. Map RS232 ports to the Virtual Ports through the card slot sub menu.
3. Map the Virtual Ports to the T1/E1/FOM time slots on the System Setup TSI Map Setup.