DCB, Inc.
2949 CR 1000 E
Dewey, Illinois
61840
217.897.6600 Tel
800.432.2638 Toll Free
217.897.1331 Fax
www.dcbnet.com
Simple Application of the 8DBRA, single host location only:
First, note that the chassis has 8DBRA cards in slots 3 and 4.
LOOP AM3440-C === Information Summary === 11:54:00
12/01/2010
Slot Card/Interface Serial Software Version Registered Card
==== ================ ====== =================== ===============
A FOM N/A FOM
B
C
D
==== ================ ====== =================== ===============
1 Quad T1 002095 V3.02.03 07/30/2010 Quad T1
2 E&M 001937 V4.02.02 07/30/2010 E&M
3 8DBRA N/A V1.01.01 05/05/2010 8DBRA
4 8DBRA N/A V1.01.01 05/05/2010 8DBRA
5 FXS 002097 V3.01.03 07/30/2010 FXS
Next, select a card. From the main menu, “U” and “3” for slot 3. No backup mode selected
yet.
SLOT 3
8DBRA P1 === Port Menu === 11:57:44 12/01/2010
Version : SW V1.01.01 05/05/2010
HW Ver.B FPGA Ver.A
Backup Mode: NO
[DISPLAY] [SETUP]
T -> Port Map Configuration
B -> Backup Setup
C -> RS232 Configuration K -> Port Map Setup
S -> RS232 Config Setup
L -> Loopback Test
Page 4