page 34
IVPC Software Reference
DS-100C Operating Manual
response “I HI=100A”
response “>”
Get Information “G”
This command gets various DS-Tracer information depending on the parameters
used. Currently two version are define:
Get Configuration
“G,C”
Example
command “G,C”
response “*”
response “123456”
tracer serial number
response “8-13-06”
date of manufacture
response “9600”
RS-232 port baud rate
response “9600”
secondary port baud rate
response “600”
nominal high-voltage range
response “150”
nominal low-voltage range
response “100”
nominal high-current range
response “10”
nominal low-current range
response “T”
thermocouple #1 type
response “T”
thermocouple #2 type
response “>”
Get Calibration Constants
“G,B”
Example
command “G,B”
response “*”
response “123456”
tracer serial number
response “8-13-06”
calibration date
response “0.6”
0.6V voltage constant (NA)
response “6.1056”
6V range voltage constant
response “60.1439”
60V range voltage constant
Summary of Contents for DS-100c