Ver 2.0 and up
iBoot
Page 4
Multiple Control Options
In addition to the Web control capabilities, iBoot features several other
means to operate automatically or under computer control. Each of these
methods is detailed in the Advanced Operation section on page 16.
Auto-Ping: The Auto-Ping feature allows iBoot to automatically detect failed
equipment and perform a timed reboot or other power control function (like
turning on an indicator or siren). You set any IP address to be periodically
Ping'ed. When iBoot no longer detects a response from the address, the
programmed power control function is actuated.
Heartbeat Monitor: Like the Auto-Ping in reverse, this feature uses a periodic
message sent to the iBoot from a device. When that message is not
received, the iBoot will perform the programmed power control function.
iBoot Control Programs: Dataprobe offers two applications to simplify
operation of the iBoot. The iBoot Control Program operates one iBoot from a
command line or application. The iBoot Control Center allows control of
multiple iBoots from one application, eliminating the need for multiple web
pages. This also allows for simultaneous control of multiple iBoots and
automation using time of day features.
Direct TCP Control: iBoot can be controlled directly via messages sent via
TCP. This feature allows programmers to add power control directly to their
application and build automated scripts in any language to operate iBoot.
The control protocol is downloadable from the Dataprobe website.