Ver 2.0 and up
iBoot
Page 19
Heartbeat Setup Page
Frequency
: Enter 1 to 999
seconds. If the heartbeat is not
received within this time it will
increment the counter.
Fail Counter:
Enter 1-99 times
the heartbeat needs to fail before
the selected action is taken.
Action
: select from
♦
None (Heartbeat not used)
♦
Power On – Latch
♦
Power On – Follow
♦
Power Off – Latch
♦
Power Off – Follow
♦
Power Cycle
♦
Power Cycle Once
Power On – Latch: Upon loss of heartbeat, iBoot will power on and remain
so until changed via the web, ibootctl.exe or direct messaging.
Power On – Follow: Upon loss of heartbeat, iBoot will power on. When the
heartbeat returns, iBoot will power off.
Power Off – Latch: Upon loss of heartbeat, iBoot will power off and remain
so until changed via the web, ibootctl.exe or direct messaging.
Power Off – Follow: Upon loss of heartbeat, iBoot will power off. When the
heartbeat returns, iBoot will power on.
Power Cycle: Upon loss of heartbeat, iBoot will cycle the power. iBoot will
wait the Frequency time; if the heartbeat does not return, the power will be
recycled again. This will continue until the heartbeat returns or Heartbeat
Monitor is turned off. Make sure your Frequency is longer than the time
required to reboot your device.
Power Cycle Once: Upon loss of heartbeat, iBoot will cycle power one time.
It will not cycle again automatically until the heartbeat returns and is lost
again.