IMPORTANT SAFETY INSTRUCTIONS

 

 
When using this product, basic safety precautions should always be followed 
to reduce the risk of fire, electric shock, and injury to persons, including the 
following: 

 

1. 

Read and understand all instructions. 

2. 

Follow all warnings and marked on the product.  

3. 

Unplug this product from the wall outlet before cleaning.  Do not use liquid cleaners or aerosol 
cleaners.  Use a damp cloth for cleaning. 

4. 

Do not use this product in an outdoor environment or near water, for example, near a bath tub, wash 
bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool. 

5. 

Do not place this product on an unstable cart, stand, or table.  The product may fall, causing serious 
damage to the product. 

6. 

Slots and openings in this product and the back or bottom are provided for ventilation to protect it 
from overheating; these openings must not be blocked or covered.  The openings should never be 
blocked by placing the product on the bed, sofa, rug, or other similar surface.  This product should 
never be placed near or over a radiator or heat register.  This product should not be placed in a built-
in installation unless proper ventilation is provided. 

7. 

This product should be operated only from the type of power source indicated on the marking label.  If 
you are not sure of the type of power supply to your home, consult your dealer or local power 
company. 

8. 

This product is equipped with a three wire grounding type plug, a plug having a third (grounding) pin.  
This plug will only fit into a grounding type power outlet.  This is a safety feature.  If you are unable to 
insert the plug into the outlet, contact your electrician to replace your obsolete outlet.  Do not defeat 
the safety purpose of the grounding type plug.  Do not use a 3-to-2 prong adapter at the receptacle; 
use of this type adapter may result in risk of electrical shock and/or damage to this product. 

9. 

Do not allow anything to rest on the power cord.  Do not locate this product where the cord will be 
abused by persons walking on it. 

10. 

Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.  

11. 

Never push objects of any kind into this product through slots as they may touch dangerous voltage 
points or short out parts that could result in a risk of fire or electrical shock.  Never spill liquid of any 
kind on the product. 

12. 

To reduce the risk of electrical shock, do not disassemble this product, but take it to a qualified 
serviceman when some service or repair work is required.  Opening or removing covers may expose 
you to dangerous voltages or other risks.  Incorrect re-assembly can cause electric shock when the 
appliance is subsequently used.  

13. 

Unplug this product from the wall outlet and refer servicing to qualified service personnel under the 
following conditions: 

a)    When the power supply cord or plug is damaged or frayed. 
b)    If liquid has been spilled into the product. 
c)  

If the product has been exposed to rain or water. 

d)  

If the product does not operate normally by following the operating instructions.  Adjust only 
those controls that are covered by the operating instructions because improper adjustment of 
other controls may result in damage and will often require extensive work by a qualified 
technician to restore the product to normal operation. 

e)  

If the product has been dropped or has been damaged. 

f)  

If the product exhibits a distinct change in performance. 

14.  

Avoid using a telephone (other than a cordless type) during an electrical storm.  There may be a 
remote risk of electric shock from lightning. 

15.  

Do not use the telephone to report a gas leak in the vicinity of the leak. 

16.  

Do not exceed the maximum output rating of the auxiliary power receptacle. 

 

SAVE  THESE  INSTRUCTIONS 

Summary of Contents for IBOOT -

Page 1: ...s Using ibootrst exe Using ARP Ping Web Browser Operation 11 Password Protection Control Status Page iBoot Setup 13 Device Settings TCP IP Settings Auto Ping Heartbeat Passwords Forgotten Password Adv...

Page 2: ...prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this prod...

Page 3: ...built in hub make installation of iBoot easy Uses for iBoot Remote reboot of any device routers servers kiosks etc The device to be rebooted need not be network attached Secure sensitive devices by ke...

Page 4: ...this feature uses a periodic message sent to the iBoot from a device When that message is not received the iBoot will perform the programmed power control function iBoot Control Programs Dataprobe of...

Page 5: ...m the wiring closet to be used for both iBoot and the device it is powering or any other device This greatly simplifies installation Use of both network jacks is optional Note iBoot supports DHCP If y...

Page 6: ...can be connected to a power strip to allow simultaneous control of multiple devices Make sure that the combined load of all controlled devices does not exceed 12 Amps for 105 125VAC or 10 Amps for 210...

Page 7: ...r end to your AC source If a power cord with a different terminating plug is required be sure it is properly rated and meets all the required local electrical standards Uplink Downlink A C Input Conne...

Page 8: ...ll as Subnet Mask and Gateway to the iBoot If you power up iBoot without a fixed static IP address the DHCP server will be able to assign an IP address This is the factory default setting for iBoot On...

Page 9: ...probe com power iboottools html To use ibootrst exe the computer running the program must be on the same subnet and network segment as the iBoot is to be programmed to Same subnet can be directly conn...

Page 10: ...the iBoot and the MAC address is the MAC Address of the iBoot The MAC Address of the iBoot is located on bottom of the unit Example arp s 63 211 86 165 00 50 c2 05 01 c1 enter new IP addr MAC addr 3 P...

Page 11: ...e methods described enter that address otherwise use the default IP address 192 168 1 254 Enter the default password PASS or your password if it has been changed A Username is not required When the pr...

Page 12: ...escribed in greater detail in the Advanced Operation section on page 16 Use the Refresh link to obtain the latest status of iBoot Using your browser s refresh button can lead to inadvertent power swit...

Page 13: ...nter either a new IP address or address 0 0 0 0 to enable Automatic IP addressing via DHCP Once you click Apply for this section also click the Reboot button that will appear at the top of the page Th...

Page 14: ...ion for Auto Ping Setup Heartbeat Setup See Advanced Operation for Heartbeat Setup Power and System Passwords Two passwords are provided The Power Password allows access to the control of iBoot but no...

Page 15: ...d use ibootrst exe All iBoot tools are available at www dataprobe com power iboottools html For security purposes you will need to power up the iBoot and complete the reset to factory defaults within...

Page 16: ...monitored and reboot it automatically when it no longer responds Use Auto Ping Remotely Put iBoot at a central facility to monitor a remote system and power up an alert when the remote device no long...

Page 17: ...ng response iBoot will power off When the ping response returns iBoot will power on Power Cycle Upon loss of ping response iBoot will cycle the power iBoot will wait the Ping Frequency if the response...

Page 18: ...that will run as a tray applet that will transmit either continuous heartbeats to an iboot A Windows dll file is also available for use by Windows applications A Windows executable that will run as a...

Page 19: ...wer on When the heartbeat returns iBoot will power off Power Off Latch Upon loss of heartbeat iBoot will power off and remain so until changed via the web ibootctl exe or direct messaging Power Off Fo...

Page 20: ...rogram To begin use first click Setup Enter the IP address for the iBoot the Port configured for the Heartbeat in iBoot the frequency of heartbeats and a Fail Count This fail count does not affect the...

Page 21: ...enter program allows control of multiple iBoot units This program provides the ideal means of monitoring and managing a large number of iBoots distributed throughout your organization Both programs ar...

Page 22: ...m2 X3C Voltage Range Auto Sensing 105 240 VAC Switched Receptacle 3 Prong Female IEC Capacity 12 Amps Max at 105 125 VAC 10 Amps Max at 210 240 VAC Network Dual 10 100 Unshielded Twisted Pair Ethernet...

Page 23: ...nical Service at 201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipmen...

Page 24: ...functions be enabled User selectable security call processing and power control features are examples of such capabilities Visit www dataprobe com power ppal html Remote Power Control Console Port Ac...

Reviews: