  Flammable  and  explosive  substances  must  definitely  be  kept  away  from  the 

water heater, they must not be at the same place.  

  After  mounting,  the  hole  opened  for  the  waste  gas  pipe  in  the  wall,  should  be 

filled with a substance resistant to burning and it should be isolated. 

  Electric connection of the heater must be grounded and 6 amper fuse must have. 

  The  wall,  which  your  water heater  is mounted,  should be strong  as  to carry  the 

weight of the water heater. 

  The installation of water heater should not be made on the power supplies 

 

 The wall, which your water heater is mounted, should be strong as to carry the 

weight of the water heater and installation metarial is fixed safetly.  

 

Be careful to avoid any accident while installing the water heater. 

For installation to suitable place according to above determined conditions; 

  Drill at least two holes of appropriate diameter from the bottom and top of the 

device according to the measurements of the water heater mounting holes  

  Fix the appropriate diameter fixing plug to the holes. 

  Drill  135  mm  waste  gas  pipe  hole  to  the  wall.  .  (Waste  gas  pipes  are  provided 

with water heater.)  

  All drilling must  be made before  water  heater  install  to  wall.  Precautions should 

be taken to prevent wastes entering the water heater that occur during drilling. 

  After  drilling  pipe  hole,  Screw  the  water  heater  from  up  and  down  to  holes  that 

you drill before. Screw more than point that is necessary. 

  Screw more than point when it is necessary

.

 

 

 

Qualifiable pipe must be used for this device. 

 

The gas flue pipe should be placed at an angle of 3 degrees with the horizontal, 

with its end inclined downwards. 

 Place the fresh air / discharge gas pipe as open side will be outside to hole which 

is drilled before for the exhaust.  

  Install the bracket part as installing one edge is to heater pipe another edge is to 

discharge pipe.

 

5.2.1. Waste Gas Pipe Installation 

5.2. Wall Installation Of Water Heater 

 

Summary of Contents for UKDAX-20VT

Page 1: ...1...

Page 2: ...yourself In case of you use LPG gas do not mount your water heater in places below the ground level Check whether your device conforms to the gas type you will use or not Provide flexible connections...

Page 3: ...er will be prevented The flame instability is prevented and the water is cooled after the flame is off with the features of blowing inside the water heater before the ignition air fan blows air for 2...

Page 4: ...4 warnings In case of fault condition it gives information about fault reason with fault code 3 THE CONFIGURATION OF WATER HEATER...

Page 5: ...5...

Page 6: ...6 The control panel is not integrated on the water heater and provides remote control opportunity Maximum of three control panels can be used in the same water heater 3 1 Control Panel Configuration...

Page 7: ...45 mm Weight 23 5 Kg The mounting of the water heater should be made by an authorized person Please contact with our authorized sales agencies or companies which are authorized by the authorized gas a...

Page 8: ...ter or the rain water to the heater the part of the waste gas pipe remaining outside the environment should be placed as to make a horizontal angle of 3 degrees Squall to waste gas pipe may cause devi...

Page 9: ...riate diameter from the bottom and top of the device according to the measurements of the water heater mounting holes Fix the appropriate diameter fixing plug to the holes Drill 135 mm waste gas pipe...

Page 10: ...ntrol base with screws from the mounting holes on the wall in the desired area Connect the connector to the cable that will provide the connection between the water heater and the control panel and pl...

Page 11: ...l be connected to water inlet of the water heater Installation of silt trap after valve is recommended for water installations which has probability of entering dirt inside of water heater from waters...

Page 12: ...qualified personnel with suitable cable section There must be a fuse with a suitable specification and6 amperes value that can completely cut off the electricity of the device The fuse should be clos...

Page 13: ...e water heater should be done by the Authorized Service For this please contact the authorized service in your region Conrol if the gas electricity and water properties are same values specified in th...

Page 14: ...splay By pressing button it can be exit by confirming matching Even not pressed button matching will automatically confirmed after a while Repeat the above steps for more remote control panel matching...

Page 15: ...t standby mode water temperature can be change with and buttons between 35 o C and 65 o C According to temperature valueeach pressing incerasing value will show dfferences Temperature Range Increasing...

Page 16: ...case completely empty the water inside the water heater against the risk of freezing as the frost protection will not work To operate the water heater again follow the steps in 6 1 2 Make sure the use...

Page 17: ...for not blocking of heat exchanger because of specification of water such as hard water Blocking of water heater exchanger is out of warranty If your pressure of installation is high because of water...

Page 18: ...s pipe during using and after a short time of using against skin burns In case of failure of your water heater do not panic and stop using the heater Disconnect the gas and the electricity Consult the...

Page 19: ...cturing defect When you have a problem during using please contact our after sales service department The unauthorized repair and the maintenance of the device will void its warranty cover Our company...

Page 20: ...ode 11 12 13 Water Temperature is over 95 o C Control Water Flow 32 Blocking of pipe duct Remove blocking and dirts at pipe duct 40 Fan operation error Call authorised service 50 Outlet water is 85 o...

Page 21: ...Authorised Services Water valve is not turn on enough Turn On water valve completely Insufficient fresh air Control device pipe Windy weather Do not use it until the wind passes Freezing water Use ag...

Page 22: ...imited irketi Nam k Kemal Mah Marmara Cad No 74 mraniye stanbul Tel 90 216 369 85 36 37 Fax 90 216 385 95 45 E Mail info daxom com Merkez Servis Nam k Kemal Mah Marmara Cad No 74 mraniye stanbul Tel 9...

Reviews: