15
Follow following steps for operate of your heater.
Turn On the water inlet valve of water heater
Open fuse of water heater
Open gas inlet valve of water heater.
Activate the heater by pressing
button. Display lights will be ON and
previous setting temperature will be seen.
Open the hot water tap. At the display of the heater it is respectively seen water
flow sign
, fan operation sign
and in a few min water heating start sign
will be seen and your water heater starts to heat water. Hot water flow time show
a change according to distance between water heater and tap.
While water heater is operating or while at standby mode, water temperature can be
change with
and
buttons between 35
o
C and 65
o
C. According to
temperature valueeach pressing incerasing value will show dfferences.
Temperature
Range
Increasing /
Decreasing
Setting Situation
35-
48°C
1°C
With
or
buttons while operation or stanby
mode it can be set.
48-
50°C
2°C
With
veya
only while standby mode can be
set
50-
60°C
5°C
With
veya
only while standby mode can be
set
The water heater can work with more than one control panel. Because of
this, it provides the opportunity to use it from different places according to
the need. When more than one control panel is connected to the water
heater, which panel will control the water heater must be determined by
6.1.4. Control Panel Priority Assignment
6.1.3. Water Temperature Changing
6.1.2. Operation Of Water Heater