3

 

 

With  digital  constant  water  setting  function:  The  water  temperature  will  remain 

constant in the degree you set. 

The fuel efficiency: As your device can operate constant setting water  

By the automatic water controlled on/off system: When the water tap is turn on, the 

water  heater  will  automatically  operate  and  the  hot  water  flow  will  be  provided. 

When the water valve is turn off, the water flow will stop and water heating will stop. 

Function   of  operating  with  low  pressure  water:  It  does  not affect  by  the  low  water 

pressure that occurs in the high apartment flats. 

The  temperature  control  adjustment  buttons:  Provide  for  users  easy  to  obtain 

different water temperature that they desire  

Function  of  high  pressure  safety  system  When  water  pressure  system  is  higher 

than it is necessary, excess water will be discharged by activation of safety valve.  

By the high temperature safety system: In case of the water getting hotter than it is 

needed, the gas will be cut off automatically and the damage of the water heater will 

be  prevented.  The  flame  instability  is  prevented  and  the  water  is  cooled  after  the 

flame  is  off  with  the  features of  blowing  inside  the  water heater  before the ignition 

(air fan blows air for 2~4 seconds before ignition) and the blowing after service (air 

fan will go on blowing air for 10 seconds after the water stops and the flame is off). 

Function Of Safe and Reliable Design of the Combustion System: Air is taken from 

outside by the fan for the purpose of providing combustion and discharged exhaust 

gas to outside again which is occurred after combustion. 

By  the  system  of  continuous  electronic  ignition:  100%  success  is  achieved  in 

ignition. 

The  device  is equipped  with  the multi-purpose safety  system.  Even  if  the  power  is 

supplied  to  the  water  heater  again  in  power  failure,  fan  failure,  the  blocking  of  the 

waste gas pipe or strong reverse wind blowing the gas will be automatically cut and 

the  automatic  ignition  system  will  be  disabled.  In  this  case  the  water  heater  will 

have to be restarted.  

Led  display:  Provides  information  about  usage.  In  case  of  operation,  you  can  see 

the  water  flowing,  operation  of  fan,  flame  formation,  water  temperature  and 

2. THE FEATURES AND THE CHARATERISTICS OF WATER HEATER 
 

Summary of Contents for UKDAX-20VT

Page 1: ...1...

Page 2: ...yourself In case of you use LPG gas do not mount your water heater in places below the ground level Check whether your device conforms to the gas type you will use or not Provide flexible connections...

Page 3: ...er will be prevented The flame instability is prevented and the water is cooled after the flame is off with the features of blowing inside the water heater before the ignition air fan blows air for 2...

Page 4: ...4 warnings In case of fault condition it gives information about fault reason with fault code 3 THE CONFIGURATION OF WATER HEATER...

Page 5: ...5...

Page 6: ...6 The control panel is not integrated on the water heater and provides remote control opportunity Maximum of three control panels can be used in the same water heater 3 1 Control Panel Configuration...

Page 7: ...45 mm Weight 23 5 Kg The mounting of the water heater should be made by an authorized person Please contact with our authorized sales agencies or companies which are authorized by the authorized gas a...

Page 8: ...ter or the rain water to the heater the part of the waste gas pipe remaining outside the environment should be placed as to make a horizontal angle of 3 degrees Squall to waste gas pipe may cause devi...

Page 9: ...riate diameter from the bottom and top of the device according to the measurements of the water heater mounting holes Fix the appropriate diameter fixing plug to the holes Drill 135 mm waste gas pipe...

Page 10: ...ntrol base with screws from the mounting holes on the wall in the desired area Connect the connector to the cable that will provide the connection between the water heater and the control panel and pl...

Page 11: ...l be connected to water inlet of the water heater Installation of silt trap after valve is recommended for water installations which has probability of entering dirt inside of water heater from waters...

Page 12: ...qualified personnel with suitable cable section There must be a fuse with a suitable specification and6 amperes value that can completely cut off the electricity of the device The fuse should be clos...

Page 13: ...e water heater should be done by the Authorized Service For this please contact the authorized service in your region Conrol if the gas electricity and water properties are same values specified in th...

Page 14: ...splay By pressing button it can be exit by confirming matching Even not pressed button matching will automatically confirmed after a while Repeat the above steps for more remote control panel matching...

Page 15: ...t standby mode water temperature can be change with and buttons between 35 o C and 65 o C According to temperature valueeach pressing incerasing value will show dfferences Temperature Range Increasing...

Page 16: ...case completely empty the water inside the water heater against the risk of freezing as the frost protection will not work To operate the water heater again follow the steps in 6 1 2 Make sure the use...

Page 17: ...for not blocking of heat exchanger because of specification of water such as hard water Blocking of water heater exchanger is out of warranty If your pressure of installation is high because of water...

Page 18: ...s pipe during using and after a short time of using against skin burns In case of failure of your water heater do not panic and stop using the heater Disconnect the gas and the electricity Consult the...

Page 19: ...cturing defect When you have a problem during using please contact our after sales service department The unauthorized repair and the maintenance of the device will void its warranty cover Our company...

Page 20: ...ode 11 12 13 Water Temperature is over 95 o C Control Water Flow 32 Blocking of pipe duct Remove blocking and dirts at pipe duct 40 Fan operation error Call authorised service 50 Outlet water is 85 o...

Page 21: ...Authorised Services Water valve is not turn on enough Turn On water valve completely Insufficient fresh air Control device pipe Windy weather Do not use it until the wind passes Freezing water Use ag...

Page 22: ...imited irketi Nam k Kemal Mah Marmara Cad No 74 mraniye stanbul Tel 90 216 369 85 36 37 Fax 90 216 385 95 45 E Mail info daxom com Merkez Servis Nam k Kemal Mah Marmara Cad No 74 mraniye stanbul Tel 9...

Reviews: