7
Model
UKDAX-20VT
UKDAX-26VT
Device Type
C13
Installation Type
Building Indoor Wall
Gas Category
II2H3 B/P
Gaz Type
LPG (G30/G31)
– NG (G20)
Gas Pressure
LPG (30 mBar)
– NG (20 mBar)
Nominal Heat Load (Q)
39,65 kW
49,7 kW
Nominal Power (P)
34,88 kW
45,35 kW
Gas Consumption
LPG
3,10 Kg/h
3,89 Kg/h
NG
4,13 m
3
/h
5,18 m
3
/h
Operation Pressure
Max.
10 Bar
Min.
0,2 Bar
Water Temperature Setting
Max.
60
o
C
Min.
35
o
C
Minimum Water Flow
3 l/min.
Electric Connections
220 V / 50 Hz
Power Consumption
50 W
Gas Inlet
3/4
”
Water Inlet / Outlet
3/4”
Fresh Air
Ø 125 mm
Exhaust Gas
Ø 80 mm
Dimensions (E*B*Y)
468*277*745 mm
Weight
23,5 Kg
The mounting of the water heater should be made by an authorized person.
Please contact with our authorized sales agencies or companies which are
authorized by the authorized gas administration (EGO, İGDAŞ, BOTAŞ,
İZGAZ,etc). Do not attempt to operate the device by yourself.
The waste gas pipe should not be installed in the general chimney or ventilation
space of the building. The waste gas pipe should definitely go outside the
building. Pipe exit should not be made to passages and corridors, narrow eaves,
ventilation and light spaces of buildings, balconies (open or closed), elevator
shafts and under protruding structure that prevent waste gas outlet, places that
4. TECHNICAL INFORMATIONS
5.1. Installation Conditions and Safety Warnings
5. INSTALLATION OF WATER HEATER