Sensor
replacement
Replace the new sensor module after 1-2 years of operation (please
check
below instructions.
Approx. 1-2 years
Sensor replacement instructions:
Step 1. Remove the Protector by Rotate it anti-
clockwise
Step 2. Unplug the sensor module
Step 3. Remove the spring clip on the new sensor
module.
Step 4. Plug the new sensor module into the PCB
Step 5. Install the Protector back by Rotate it clock-wise
END.
* Please disconnect the device before doing the following steps