Figure 13. Place the base with Epoxy on the equipment's
surface
Figure 14. Leveling it in the X direction
Figure 15. Leveling it in the Y direction
Figure 16. Leave it dry for 24 hours before installing the
sensor
* Clean the surface with alcohol;
* Apply the 2-part putty epoxy on the bottom surface of the base;
* Place the base on the surface;
* Use the leveling meter to level the surface of the base in 02 directions X and Y;
LEAVE IT COMPLETELY DRY AND HARDEN IN AT LEAST 24 HOURS
* Screw the M6 screw and install the sensor module.
Note: the adhesive base is for a flat surface only or a curved surface with a radius larger than 500mm.
5.3 Connect the M12 cable (for LoRaWAN of Sigfox Version)