Installation
(for qualified installers only)
59
© Travis Industries
9/25/17-1468
Maestro
Wiring Diagram
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
Warning:
Do not disconnect or alter the air pressure switch wiring. This is a safety component that is critical to the
safety of this fireplace.
Exhaust Blower
Junction Box
White
Capacitor
Green
Black
Black
Black
Fireplace Junction Box
Power Vent
Controller
Exhaust Blower
Junction Box
Exhaust Damper
Wire Harness
Blue
Black
Brown
Red
Brown
Blue
Black
Blue
Black
120 VAC
Power In
White
F-OUT
F-IN
Gray
Black
Red
Fuses*
(see below)
Black
3.15A
FUSE
Secondary
Base
Integrated
Fireplace
Control (IFC)
Category 2
3.15A
FUSE
Green
Fireplace Junction Box
Spark
Rod
Appliance
Ground
Green
Yellow / Green
120 VAC
Power In
White
Flame
Detect
Black
White
Green
Orange
Air
Pressure
Switch
24 Volt AC
Transformer
Intake
Dampers
Power
Exhaust
Primary
Base
Integrated
Fireplace
Control
(IFC)
Blue
Red
Black
White
Black
Purple
Black
White
Black
White
Blue
Blue
Yellow
Yellow
* Fuse Layout
Transformer
(1 Amp)
Ex. Rheostat
(6.3 Amp.Sl.Bl.)
Power Exhaust (6.3 Amp.Sl.Bl.)
Exhaust Damper
(1 Amp)
Intake Damper
(1 Amp)
Exhaust
Damper
Thermodisk
Auxiliary
Board
Black
120 VAC
Power In
White
Green
24 Volt DC
Transformer
Touch
Screen
Optional De-Humidifier
Optional Heat Exchanger
Optional Overhead Lights
120 VAC
Power In
Black
White
Green
LED
Light
Strips