38 Installation
(for qualified installers only)
© Travis Industries
9/25/17-1468
Maestro
Approved Vent Configurations
The fireplace vent must meet the following requirements (measured from base of fireplace):
Minimum Vent Length = 3’ (1 M) - Interior blower requires a minimum 5’ (1.6 M) vent length
Maximum Horizontal Run = 100’ (30 M)*
NOTE: Vent does not require any vertical rise along its run.
Maximum Vertical Rise = 100’ (30 M)* (measured from base of fireplace)
Maximum Vertical Drop Below Base of Fireplace = 6’ (2 M)*
NOTE: The downward vent sections may not exceed 10’ total.
Maximum
90˚ Elbows = 4 (note: two 45˚ elbows count as one 90˚ elbow)
Use the table below to determine which blower must be used.
*
If you wish to place the termination outside the shaded regions, or if additional elbows are
required, you must contact Travis Industries to verify vent configuration.
Compatible Exhaust Blower
36 x 36
36 x 58
Category 1
RS12 or Inline 160
RS16 or Inline 180
0 feet
0 feet
40 feet (12m)
20 feet (6m)
-6 feet (-2m)
40 feet (12m)
20 feet (6m)
60 feet (18m)
80 feet (24m)
100 feet (30m)
60 feet (18m)
80 feet (24m)
100 feet (30m)