30 Installation
(for qualified installers only)
© Travis Industries
9/25/17-1468
Maestro
Installing the TouchSmart Controller
Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace.
The included junction box is used to mount the TouchSmart controller (see page 31). Mount the
junction box in an accessible location to allow the user to operate the fireplace.
Route the CAT5 harness to the junction box (harness is available in various lengths – see page 8).
Route the wire through the junction box and attach to the TouchSmart controller.
NOTE: Install 3” to 6” of slack in the harness wires to allow for switch/controller access and removal.
Keep the cable 12” (300mm) away from high voltage (120v) wiring to prevent interference.
The TouchSmart controller is held in junction box using (3) magnets.
Caution
:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
Secure the CAT5 cable to the mounting plate
with lock tie(s). This prevents the cable from
falling into the wall cavity when the cable is
disconnected from the touch screen.
CAT5 Cable
(Available in Various Lengths)
Do not route the cable near 120v wiring, or
the the vent (hot surfaces).
Mounting Plate Box
Mounting Plate
Touch Screen
12"
(300mm)
Keep cable 12"(300mm)
away from high voltage
(120v) wiring to prevent
interference.
NOTE:
120v Wiring